PCX-EXT-W/BK

External Proximity Tag Reader 

 

0845 6434 999 (UK). +44(0)1709 535 225

  

 [email protected]   

 

www.pyronix.com   

Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK  

 

       

RINS1632-1

EN50131-3:2009

EN50131-1:2006+A1:2009

PD6662:2010

Security Grade 3

Environmental Class IV

E N G L I S H

Installation Notes

References:

Specification

Warranty

Product Warning Information

Compatible Products

.

NOTE

: The reader module can be mounted on typical building materials; such 

as wood, PVC, brick or metal etc. If you do encounter any problems with 

different surfaces, please contact [email protected] 

START

END

Black

: D1-. 

Red

: D2+. 

Yellow

: D3. 

Blue

: D4.

Brown(1), Orange(2), Green(3): 

Used for addressing.

 Light Blue:

 Lock Relay. 

Pink: 

Request to Exit. 

White, Grey: 

Door Monitoring. 

Purple: 

Door Alarm Monitoring

INSTALL KEYPADS/READERS (Programming Menu Required).

 Use the 

brown, orange and green wires

 to address the Reader.

Connecting a Mag Lock: 

Use the 

light blue

 wire. The diagram show the 

relay mag lock control switching positive.

Connecting a Request to Exit: 

Use the 

pink

 wire. The diagram shows a 

normally open request to exit button, and takes “0V” from the control 

panel.

Connecting Door Monitoring: 

Use the 

white

 and 

grey

 wire. The door 

monitor input needs to be programmed as the first input number of the 

reader address (programmed as “Entry Delay”). If the door contact is 

forced open without presenting a valid tag or pressing the push to exit 

button, then the panel will go into an alarm. NOTE: The DEOL values 

must be 4K7, 2K2 as shown. This does not affect the control panel DEOL 

values.

Connecting Door Alarm Monitoring: 

Use the 

purple

 wire. When the door 

monitor exceeds the door open time or if the door is forced open then 

the alarm PGM will generate an alarm. The input at the control panel 

should be programmed as “24 Hour” or “Day Alarm” and the attribute 

programmed as “Normally Open”.

Lock Open Time: 

This is the time the door release is going to be active 

when a valid tag is presented.

Door Open Time: 

This is the time the door is allowed to be open before 

triggering an alarm.

The External Prox Reader

D1-
D2+
D3
D4

RS485 BUS: 1km

D1-
D2+
D3
D4

D1-
     D2+
            D3
                     D4

D1-

D3
D4

D1-  D2+  D3    D4

D1-  D2+  D3    D4

D1-  D2+  D3    D4

PCX-RIX8+/PSU

PCX-/PSU

PCX-ROX8R8T

PCX-RIX8+

PCX-RIX8i

PCX-LCD/EX

AUX

12V Lock 

Relay

PCX-EXT-W

PCX-PROX/INT

PCX-RIX32-WE

D1-  D2+  D3    D4

Supply voltage: 

9-15VDC

Current consumption: 

Max 22mA

Input status when reader is Arm/Disarm or Sub-Area Control:

Input:

 Programmable 

Input EOL resistor value:

 DEOL or SEOL. Alarm=4K7 / Tamper=2K2

Input status when reader is used as Access or Door Entry Control:

Input: 

 Programmable 

Input Function:

 Door monitor feature. Door opening time limit is programmable from 

the Engineer menu.

Input DEOL resistors: 

NC

Input 2: 

Not programmable

Output 1:

 Not programmable. Activates the Door Lock Relay

Output 2: 

Not programmable. Door monitor alarm activation (forced or open for longer 

than programmed time).

Output 1/2 Normal state:

 Floating

Output 1/2 Active state:

 0V

Colour and Casing:

 

3mm ABS (Black: PCX-EXT-BK, White: PCX-EXT-W)

Temperature

Storage:-10°C to 50°C 

Certified

-10°C to 40°C

Nominal: -25°C to 60°C

Dimensions (H x W x D):

 

85 x 85 x 21mm

IP65 Rated

If the control panel fails to arm, this is indicated by a broken tone on the external 

proximity reader and the red LED will not illuminate. If this occurs, please check the 

information at the nearest keypad.

Note: Access control falls outside the scope of EN 50131

This product is sold subject to our standard warranty conditions and is warranted 

against defects in workmanship for a period of two years (batteries excluded). In the 

interest of continuing care and design, Pyronix Ltd reserves the right to amend 

specifications, without giving prior notice.

For electrical products sold within the European Community. At the end of the 

electrical products life, it should not be disposed of with household waste. Please 

recycle where facilities exist. Check with your Local Authority or retailer for recycling 

advice in your country.

The PCX-EXT-W/BK can be connected to the following control panels/devices:

PCX 46, PCX 76i, 162i, 280i,IP and Enforcer 32-WE.

Each control panel/device connects via the RS485 bus terminals: D1-,D2+,D3,D4

NOTE: For information about programming tags to the external reader, please see 

the control panel user manual.

 

Magnetic Contact

Door Monitoring

4

K

7

RS485 BUS: 1km

D1- 
D2+ 
D3
D4

Reader

Addressing

Wires

Door Monitoring

Brown(1):

Orange(2):

Green(3):

Light Blue: Lock Relay 

Pink: Request to Exit

White: 

Grey:

Purple: Door Alarm Monitoring

0V (D1-)

ID1

0V (D1-)

ID2

0V (D1-)

ID3

0V (D1-)

ID4

0V (D1-)

ID5

0V (D1-)

ID6

0V (D1-)

ID7

1K

2

K

2

INSTALL KEYPADS/

READERS?

Device Type?

Reader     [1]

Device Address?

              0

Device Arm Area?

          [A   ]

Device Disarms?

          [A   ]

Device In Area?

          [A   ]

Reader is:

Entry Control[4]

Lock Open Time

          [005]

Door Open Time

          [010]

Door Name?

Enter Number:

Device 1

>5s

5s

>10s

<10s

EXIT TIMER

1K

>5s

>10s

ATE INPUTS

ATE INPUTS

PCX

PCX

ATE INPUTS

PCX

OFFICE

>5s

5s

<10s

5s

D2+