Section 4: Manager Mode 

NOTE: You can only enter manager mode while the system is disarmed. 

4.1 Entering Manager Mode 

Enter Manager Mode by keying your 4-digit manager code. 

You then have a choice of: 

SET DATE AND TIME? 
OMIT ZONES? 
CHANGE CODES? 
REVIEW LOGS? 
WALK TEST? 
BELL TEST? 
TEST PHC COMMUNICATIONS? 
ENGINEER MODE? 
EXIT MANAGER MODE? 

Pressing the 

 key will take you from one choice to the next (as well as escaping from within a choice). Pressing 

the 

 key will take you into a choice (as well as accepting an option when within a choice). 

4.2 Changing Time and Date 

D

C

B

A

SET DATE & TIME?

 

Press 

D

C

B

A

YEAR (00-99)

                             [03]

 

Enter the year (e.g., ‘03’ for 2003). Press 

D

C

B

A

MONTH (01-12)

                             [06]

 

Enter the month (e.g., ‘06’ for June). Press 

D

C

B

A

DAY (01-31)

                             [20]

 

Enter the day. Press 

D

C

B

A

HOURS (00-23)

                             [16]

 

Enter the hours in 24 hour format (e.g., ‘16’ for 4 

o’clock in the afternoon). Press 

Содержание PCX-12

Страница 1: ...VERITEC P2 The award winning sequential confirmation detector PCXUSER GUIDE THIS GUIDE SUPPORTS PCX 12 22 44 WWW PYRONIX COM Designed and manufactured utilising by TM TM TM...

Страница 2: ...nd design Pyronix reserve the right to amend specifications without giving prior notice Pyronix Limited Pyronix House Braithwell Way Hellaby Rotherham S66 8QY ENGLAND Tel 44 0 1709 700100 Fax 44 0 170...

Страница 3: ...stem 6 2 5 Partial Arming of the System 6 SECTION 3 ADVANCED FUNCTIONS 7 3 1 Chime Function 7 3 2 Deliberately Omitting a Zone 7 3 3 Ignoring an Open Zone 8 3 4 Keypad Personal Attack 8 SECTION 4 MANA...

Страница 4: ...ll arm and disarm the system You can also use the keypad to program the system for your individual needs including arming different partitions adding codes and tags and reading system messages MAINS F...

Страница 5: ...mps to clearly indicate what is happening LED Indication Table A B C D Green Supply LED Red Alarm LED Red Tamper LED Yellow Fault LED Green Arm disarm Partition A Partition B Partition C Partition D T...

Страница 6: ...nset The Disarm lamp will light if the PCX is completely disarmed steady or if some partitions remain armed flashing Unset Power T ag Alarm Tamper Fault Unset 1 3 Using a Tag The PCX High Security Pro...

Страница 7: ...e Enforcer PI Equinox PI and Magnum PI ET MMUNE ET MMUNE E T MMUNE Close all doors and windows 2 2 Partitions The partitions feature of the PCX allows you flexibility in using your system The installa...

Страница 8: ...disarm and the entry exit tone will cease 2 5 Partial Arming of the System In some circumstances you may wish to arm only part of the system leaving some of the building disarmed For example at night...

Страница 9: ...taller you can leave this zone unarmed whilst arming the rest of the zones in that partition Follow the procedure below 1 Enter your PIN code or present your tag and press the key The system starts to...

Страница 10: ...The display shows D C B A Omit zones 01 3 Enter the zone you wish to omit Always remember to use a leading zero for zones 01 09 The display shows D C B A Omit zones 02 Zone 02 4 The system will now w...

Страница 11: ...E EXIT MANAGER MODE Pressing the key will take you from one choice to the next as well as escaping from within a choice Pressing the key will take you into a choice as well as accepting an option when...

Страница 12: ...ode for the user A code can be 4 5 or 6 digits long Press D C B A User Type User 0 Enter the user type Choose from 0 User or 1 Master User Press D C B A User Partitions ABCD Choose the partitions the...

Страница 13: ...r to the right 1 key once to write an a D key once to move the cursor to the right 4 key twice to write an n Press the key The display will show D C B A User Number 02 Press the key to return to the m...

Страница 14: ...ime will be played and that zone will be removed from the scrolling list D C B A Walk Test Completed When all the detectors have been activated the display shows Walk Test Completed Press to complete...

Страница 15: ...ll be delighted with your PCX Alarm System For your personal reference here is a record of the relevant service information Service Company Date of Installation Day Month Year Site Reference 24 Hour S...

Страница 16: ...fee for this service is collected automatically via a premium rate number when the PCX System makes its regular authorization and routing call to the Messaging computer Should this call fail the disp...

Страница 17: ...PCX User Manual RINS459 2 15 Engineer Programming Table No 00 JAL 1234 ABCD ARM DISARM NO 1 2 8 Manager Name Code Type Areas Flexi Access RDR Attributes...

Отзывы: