background image

Step 3: 

x

At the 

control panel

 measure the DC voltage between the 0 Volt Bell Hold off connection, and 

the Bell Trigger output connection. If the measured DC voltage is 12 Volts or above, then fit a 
1K resistor between the 0 Volt Bell Hold off connection and the Bell Trigger output connection. 
Now move to 

STEP 4.

 If the measured DC voltage is 0 Volts then move straight to 

STEP 7

 

Step 4: 

x

At the control panel measure the DC voltage across the 1K resistor which has been inserted 
between the 0 Volt Bell Hold off connection and the Bell Trigger output connection . The 
measured DC voltage reading will be close to the readings shown in the table below.   

APPROXIMATE MEASURED VOLTAGE         

 

REQUIRED MONITORING RESISTOR 

6.8 Volts 

470 ohms 

4.5 Volts 

1K 

4.2 Volts 

1K 

3.4 Volts 

No resistor required 

3.1 Volts 

No resistor required 

2.3 Volts 

No resistor required 

0 Volts 

See STEP 7

 

 

Step 5: 

x

At the control panel remove the 1k resistor from the 0 Volt Bell Hold off connection and the 
Bell Trigger output connection. Replace the 1k resistor with the chosen value of resistor from 
the table above. Insert and screw down the Bell Trigger wire into the control panel Bell output 
connection.  Make a final measurement of the DC Voltage at the 

Invincibell

 

between the 0 Volt 

Bell Hold off connection and the Bell Trigger output, the Bell Trigger Monitor voltage will read 
between 1.6 Volts and 3.0 Volts DC. 

 

BELL TRIGGER OUTPUT

CONTROL PANEL

0V HOLD OFF NEGATIVE

BELL TRIGGER OUTPUT

CONTROL PANEL

0V HOLD OFF NEGATIVE

13.0V

1

K

BELL

-

+

12v

INVINCIBELL

1.6V-3.0V

Отзывы: