10.5 

Battery Capacity 

It is recommended that the rechargeable battery used with the Atlas 8 control panel should be capable of powering the 
alarm system for a minimum of 8 hours, and that this time period should include 20 minutes of bell/strobe operation.  
The minimum battery capacity should be calculated from the current consumption of the individual system components.   
 
A typical example based on the following individual parts is shown below: 
 

 

 

Non alarm current for control panel  (7hrs 40min) 

 

: 130mA (0.130 A)  

 

Steady state current for detectors   

 

 

: 120mA (0.120 A) 

 

 

(e.g. 8 x 15mA for 8 hours - Pyronix PIRs) 

 

Typical standby current for external sounder   

 

: 50mA (0.050 A) 

 

(e.g. Self Actuating Bell for 8 hours) 

 

Typical on state current for external sounder (20 mins) 

: 350mA (0.35 A) 

 

Alarm state current for control panel (20 mins) 

 

: 130mA (0.13 A) 

 

Typical current for external strobe (8 hours)   

 

: 150mA (0.15 A) 

 
 

 

 

 

 

 

Alarm condition for 20 mins (0.333 hrs) 

 

 

 

Alarm state current for control panel  

 

 

: 0.130 

 8 

detectors 

@15mA 

    : 

0.120 

 External 

sounder 

     : 

0.350 

 External 

strobe 

     : 

0.150 

 

Standby current for external sounder 

 

 

: 0.050 

 Single 

remote 

keypad 

    : 

0.015 

 

 

 

 

 

 

Required capacity for alarm condition 

 

 

= 0.815 x 0.333 = 0.271 Ahrs 

 

 

 

Capacity required for standby 7hrs 40 mins (7.67 hrs)  

 

 

 

 

Non alarm current for control panel   

 

 

: 0.130 

 8 

detectors 

15mA 

 

    : 

0.120 

 External 

strobe 

     : 

0.150 

 Standby 

for 

external 

sounder 

   : 

0.050 

 Single 

Remote 

keypad 

    : 

0.015 

 
 

Required capacity for standby condition 

 

 

= 0.465 x 7.67 = 3.57 Ahrs 

 
 

Total minimum required battery capacity 

 

 

= 0.271 + 3.57 = 3.84 Ahrs 

 

 

For this example it is recommended that you use a battery of not less than 6 AH. 
 
10.6 

End of line resistors 

When a Sensor, and tamper are wired into the same zone this is called an End of Line Zone (EOL).  The Atlas 8 panel 
uses resistors on all of its end of line zones. Two resistor values are used, these are 2K2 and 4K7.   
To identify the two resistors, coloured bands on the body are used. These are as follows: 
  
 2K2 

 

 

 

 

 

 

     

 4K7 

Fourth Band

Red

Red

Red

Fourth Band

Yellow

Violet

Red

 

 
 
 
Any unused zones should NOT be left open circuit. These should have a 2K2 resistor inserted, Refer to diagram 10.6.1, 
page 17. 
 
NOTE:

 when the panel and sensors are wired using end of line resistors, to enable the zone to detect alarm and tamper, 

the system must be configured in System Option 1. Refer to Page 23. 
10.6.1  Atlas 8 End Of Line Resistor Wiring Diagram. 
 

Содержание ATLAS 8

Страница 1: ...Rins171 Issue 6 INSTALLATION INSTRUCTIONS Lcd Remote Keypad Pyronix Ltd MARCH 00 This Product is approved for use in the Residential Commercial and Light Industrial Environment...

Страница 2: ...gn Pyronix reserve the right to amend specifications without giving prior notice A copy of our warranty can be obtained from the above address 3 URQL LPLWHG 3 URQL RXVH UDLWKZHOO D HOODE 5RWKHUKDP 6 4...

Страница 3: ...ons 16 10 8 Powering Up The panel 16 10 9 Atlas Double Pole Wiring Diagram 17 10 10 Atlas End of Line Wiring Diagram 18 11 PROGRAMMING 19 11 1 Factory Defaults 19 11 2 Entering Engineer Mode 20 11 3 S...

Страница 4: ...eporting Codes 25 11 17 Digicom Codes 26 11 18 Keyswitch Set Configuration 26 11 19 Group Reporting Telephone Allocation 26 11 20 Engineer NVM Reset 27 11 21 Follow Select 27 11 22 Exiting Engineer Mo...

Страница 5: ...g 3 2 Master User Level Enables All Limited User facilities 4 Clearing of event log if allowed by the Engineer 5 Omitting zones 6 Alteration of both Limited and Master User codes 7 LED Strobe Bell Ext...

Страница 6: ...try Exit zone then an alarm will be generated immediately Immediate This is a zone which will when triggered wil create an alarm when the panel is set Omit If a zone is programmed as an Omitted zone b...

Страница 7: ...Walk test The walk test function allows each of the Set modes to be checked in order to verify that all the intruder detectors on the alarm system are functioning correctly When undergoing a walk test...

Страница 8: ...tlas on the same line as an answering machine The default setting is AMC on To remotely access the Atlas in AMC mode dial in and wait for a single ring then hang up and wait for at least 10 seconds bu...

Страница 9: ...igit access code required by the alarm company in order to access the Atlas 8 during an uploading or downloading operation Reporting Codes These are unique two digit or single digit numbers used by th...

Страница 10: ...will also emit a short duration of sound upon disarming Default value OFF Bell Time Minutes Seconds This option allows for very short bell durations Default value Minutes AC Fail Delay This option del...

Страница 11: ...carefully Plan out the various areas and degrees of protection required from each zone It is important to decide which type each zone should be if selective sets are to be used Work out the cable rou...

Страница 12: ...kaging containing the control panel and PCB Push in the PCB support posts from the rear of the panel as shown If required assemble the tamper switch from the optional kit of parts as indicated If nece...

Страница 13: ...l mounting hole using one of the screws and plugs from the screw pack If possible use a spirit level or some other means to position the control panel squarely then drill two more holes into the wall...

Страница 14: ...ed BAT on the PCB Battery Positive Battery Negative 10 3 Bell Strobe and Extension Speaker Connections Bell Positive Bell Trigger Strobe Positive Strobe Negative Speaker Positive Speaker Negative NOTE...

Страница 15: ...r external sounder 0 050 Single remote keypad 0 015 Required capacity for alarm condition 0 815 x 0 333 0 271 Ahrs Capacity required for standby 7hrs 40 mins 7 67 hrs Non alarm current for control pan...

Страница 16: ...to protect all the zone tamper wiring Up to ten sensors or door contacts may be wired on each zone 10 7 Telephone Connections T 1 R 1 TIP RING 10 8 Powering Up Your Panel RKP a Connect the battery lea...

Страница 17: ...7 7 1 7 7 1 H J 0 0 7 2 1 9 1 5 2 2 0 7 7 5 5 5 3 521 3 5 7 0 3 5 5 0 6 8 3 3 3 521 3 5 7 7 67 5 0 6 3 5 1 6 3 H J 6 6 2 1 7 0 3 5 5 0 6 8 3 3 7 1 6 2 1 6 3 5 2 3 7 2 1 7 7 5 7 7 5 5 6 7 2 7 3 2 1 6 6...

Страница 18: ...5 6 7 2 7 3 2 1 6 6 7 0 3 7 0 3 5 2 1 1 7 2 1 6 6 2 8 5 7 2 2 1 3 5 2 5 0 0 2 5 7 0 3 5 7 3 2 1 1 7 2 5 5 3 6 3 H J 6 6 2 1 H J 0 0 7 2 1 9 1 5 2 2 0 7 1 6 2 1 6 3 5 2 3 7 2 1 2 3 7 2 1 6 5 1 9 0 1 7...

Страница 19: ...d Of Line Resistor Programmable Outputs Off System Option 1 End Of Line Zone User Log Reset Disabled Tone Dial Internal Sounder Only On Tamper Activation System Option 2 24 Hour Test Dial Dial In Spar...

Страница 20: ...mode Use the link supplied to connect the NVM reset pins together and enter on the key pad remove the link The system is now back to factory default settings 11 5 Setting the Panel when Mains Fails Un...

Страница 21: ...e new Engineer Code gives an audible acceptance tone then the new Engineer Code again gives an audible acceptance tone If an incorrect key is entered an error tone will be given and the function ended...

Страница 22: ...ard handshake filters Audible PA zones Press to accept 11 11 5 System Option 3 Enter followed by The RKP display will toggle and X as the numbered keys are pressed indicating the selection made Key Pr...

Страница 23: ...ically when the last digit is entered 11 14 Customer Account Code Issued by Central Monitoring Station Enter HQWHU VHTXHQFH followed by the 4 digit code e g 4 digit 11 15 Downloading Access Code Enter...

Страница 24: ...set reporting codes To disable an event insert blanks by pressing the key in place of the two digits Examples Set A Set B Set C Set D Duress Set Duress Unset Confirmed alarm code To use HEX codes use...

Страница 25: ...n event insert blanks by pressing the key in place of the two digits Examples P A alarm entered at RKP Fire alarm entered at RKP Engineer mode entered Bell fuse failure Auxiliary fuse failure Battery...

Страница 26: ...tion requires all four Groups to be programmed Enter Group 1 Alarm Codes Now select where you require the Alarm Codes to be reported to No reporting for group Report to telephone number 1 backup to nu...

Страница 27: ...ill work 11 21 Follow Select Enter This function is used in conjunction with Programmable Output 1 and 2 option 5 Follow Zone Enter the zone to be followed Enter for zones 1 to 8 or if no zone is to b...

Страница 28: ...be emitted every 5 seconds when the panel is in day mode Press a function key to stop the error tone The fault will remain on until the fault has been corrected To determine the fault go into the log...

Страница 29: ...00mA Strobe 500mA PR1 PR2 250mA Alarm bell time 2 to 20 minutes software programmable Zone type Normally closed loops which activate when opened or short circuit Zone loop current 0 76 to 1 03mA Zone...

Страница 30: ...1 System option 2 System option 3 Spare Re Sets First telephone number Second telephone number Customer account code Downloading access code Zone alarming reporting codes Zone tamper reporting codes S...

Страница 31: ...activation System Option 2 1 Default 24 hour test dial 2 Default no dial in 3 Default Standard filters 4 Default Audible P A System Option 3 1 Default User NVM reset 2 Default Open zones not displaye...

Страница 32: ...Alarm Zone 5 Alarm Zone 6 Alarm Zone 7 Alarm Zone 8 Alarm Tamper Alarm Reporting Codes Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper...

Страница 33: ...User 5 Set User 6 Set User 7 Keyswitch User Unset Reporting Codes Unset User 1 Unset User 2 Unset User 3 Unset User 4 Unset User 5 Unset User 6 Unset User 7 Keyswitch Maintenance and Priority Codes P...

Страница 34: ...storal Reporting Codes User code Restoral Bell Timeout Restoral Battery Restoral A C Restoral Test Transmission Digicom Codes Keyswitch Set Configuration Group Allocation Group 1 Group 2 Group 3 24hr...

Страница 35: ...Rins171 Issue 6 Page 35...

Страница 36: ...Page 36...

Отзывы: