System Option 4
Bell Squawk-
Upon expiry of the exit time, if the panel sets OK the bell will emit a short duration of sound. It will also emit a short
duration of sound upon disarming.
Default value - OFF.
Bell Time Minutes/Seconds-
This option allows for very short bell durations.
Default value - Minutes.
AC Fail Delay
This option delays the display and transmission of AC faults. Generally used in areas where there is an unstable
mains supply.
Default value – 0 minutes
INSTALLATION AND WIRING
Before beginning any installation work read through this section carefully. Plan out the various areas and degrees of
protection required from each zone. It is important to decide which type each zone should be if selective sets are to be
used. Work out the cable routes avoiding mains cabling and consider the chosen position for the control panel.
8.1
Plan View With Cover Removed
17
V
~
+B AT-
B+ B A
Z1
Z2
Z3
Z4
-AUX +
K D PR1
TIP RING T-1 R-1
RESE T
98001.CDR
Tamper Select Link
Bell Fuse
Power LED
Aux. Fuse
NVM Reset Link
Tamper Switch