CONNECTIONS - NATURAL GAS (NG)

 

 

The supply hose is equipped with a 3/8” flare fitting and should be connected to a CSA certified manual shut off valve. 

An adapter fitting may be required. 

 

 

 

 

This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during 

any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). 

 

The supply gas hose must not be run along areas where it may be a tripping hazard or subjected to accidental damage 

(such as pathways, driveways and lawns). 

 

Do  not  bury  the  gas  supply  line  supplied  by  the  manufacturer  underground.  They  are  not  approved  or  certified  for 

underground use. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание GAS4160-B

Страница 1: ...PLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediately After leaving the area call your gas supplier or fire department Fa...

Страница 2: ...4 Connections liquid propane LPG 5 Connections natural gas NG 6 Conversion instructions propane to natural gas 7 Battery installation 8 Leak test 8 Lava rock installation 9 Operation instructions 10...

Страница 3: ...burner and components carefully for any signs of damage or loose connections If any damage is found contact the retailer and report it immediately Tighten any loose connections and perform a leak tes...

Страница 4: ...es with the standard for Quick Disconnect Devices for Gas Fuel Appliances ANSI Z21 41 CSA6 9 There MUST be a pressure regulator with a maximum output of pressure of 14 W C installed in line When an ap...

Страница 5: ...round it clear and free from combustible materials Gasoline and other flammable vapors and liquids must be kept a minimum of 25 feet away and auxiliary propane tanks should be stored at a minimum of 1...

Страница 6: ...ram A B Tighten down the screw on the side of the tank seat to secure the propane tank refer to diagram B C Place the propane tank a minimum of 60 152 4CM away from the fire feature refer to diagram C...

Страница 7: ...d This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal t...

Страница 8: ...kit onto the rating plate on the converted appliance 8 Perform a leak testing of the converted appliance before operating the converted appliance see the LEAK TEST section of page 8 of the manual Natu...

Страница 9: ...soap to one part water 2 Make sure the appliance control knob is in the OFF position 3 Open the gas supply to the fire table 4 Apply the leak testing solution by spraying it on joints of the gas deliv...

Страница 10: ...bag into the burner in order to prevent damage to the fire table to prevent clogging the burner ports with dust and to prevent getting debris in the ignitor box Only place enough lava rock to cover t...

Страница 11: ...se of the fire table because they are the two areas that gas would most likely accumulate in case of a leak If you smell gas do not try to light the appliance Immediately close the manual shut off val...

Страница 12: ...ight is 8 to 13 USING A LONG MATCH OR BBQ LIGHTER 1 Make sure that the burner control knob is in the OFF position 2 Prior to lighting clear some lava rock away from the burner ring with a garden trowe...

Страница 13: ...the hose assembly for excessive abrasion or wear The hose assembly must be replaced prior to the appliance being put into use if any evidence of damage is found The replacement hose assembly must be o...

Страница 14: ...the setting of the thermocouple refer to diagram 2 and confirm the connection is tight refer to diagram 3 C The gas pressure is too low Have a gas technician do a pressure test on the supply line D A...

Страница 15: ...orrectly or depleted Ensure that a fresh AA battery is installed Positive side facing outward toward the sparker cap B There is corrosion on the battery contacts Check contact at the bottom of the bat...

Страница 16: ...de 4 Ground wire 5 Thermocouple 6 Ignitor cover 7 Air mixer 8 Air shutter 9 Orifice 2 16mm for propane 3 73mm for natural gas 10 Orifice holder 11 Natural gas fitting 12 Stainless steel flex pipe 13 B...