TIMETRAX™ SYNC 7000/7000BDL110 MASTER CONTROL
Installation Instructions
Wire 24V DC Bells or Horns to the 7000
terminal labeled 24 VDC using 16-18
gauge wire (part #41449 sold separately)
Route the bell wire through the
cable channel located on right side
or bottom of 7000 case. A total of 35
bells or 20 Horns can be connected
to the circuit if using Pyramid bells
(part #41361, 41392) and horns (part
#41362).
Use the following table to set a bell/
horn schedule. Program up to 300
bell/horn events.
1
1
SELECT
SET-UP INSTRUCTIONS
To change or set feature,
press SELECT until desired
feature is displayed.
Use or to change
feature.
1
2
DATA
POWER
After displayed feature is
changed, press SELECT to
change other feature &
return to main display.
3
24 VDC
+
-
41301A
pyramidtimesystem.com
RED (+) BLACK (-)
3
2
2
1
DC BeLL COnneCTiOn
The 7000 will provide power to 24V DC bells or horns, up to 800 milliamps (mA) per event.
SELECT
SET-UP INSTRUCTIONS
To change or set feature,
press SELECT until desired
feature is displayed.
Use or to change
feature.
1
2
DATA
POWER
After displayed feature is
changed, press SELECT to
change other feature &
return to main display.
3
24 VDC
+
-
41301A
pyramidtimesystem.com
2
NC
COM
NO
ON
0
115 230
24
Ø
LINE
NEUTRAL
LOAD
AC BeLL COnneCTiOn
CAUTION: 110V BELL RELAY MUST BE INSTALLED
BY A LICENSED ELECTRICIAN.
Please refer to diagram.
7000
110V
Relay
2
BELL CONNECTION & SCHEDULE
11
BELL CONNECTION
888.479.7264
Line = Black
Neutral = Red or White
POWER IN 110V AC