![PYLE Audio PHDVR40 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/pyle-audio/phdvr40/phdvr40_operation-manual_1631430013.webp)
Operation Manual-4CH Duplex DVR system
13
A: [ALARM DURATION]
It sets the alarm duration time (in
seconds) after alarm is activated.
Value at
“
05
、
10
、
15
、
20
、
25
、
30
、
CONT
、
OFF
”
(in seconds). Default at
“
OFF
”
.
By changing the value in the ALARM
DURATION, you can adjust how long the
alarm will last in seconds. The alarm device should be installed.
B: [BUZZER DURATION]
It sets the buzzer duration time (in seconds) after alarm is activated.
Value at
“
05
、
10
、
15
、
20
、
25
、
30
、
CONT
、
OFF
”
(in seconds). Default at
“
OFF
”
. When
“
buzzer
duration
”
is
“
cont
”
, the buzzer will work continuously.
C: [EVENT REC DURATION]
It sets the record time of duration (in seconds) after sensor recording or motion recording or
MD & sensor recording is activated.
Value at
“
05
、
10
、
15
、
20
、
25
、
30
”
(in second).
D: [MOTION DETECTION]
[CHANNEL]
Select the channel (1,2,3,4) for recording
mode by internal motion.
[SENSITIVITY]
It adjusts the sensitivity of the built-in
motion sensor on the DVR system while
recording. The higher the number, the
higher the sensitivity is. Value at
“
1
、
2
、
3
、
4
、
Off
”
. The maximum sensitivity level is 4.
[MOTION AREA]
Use this option to select the range of motion detection area.