background image

 

11 

  MAINTENANCE   

 

Note:  Turn off the unit and unplug it before any maintenance or repair begins to avoid electric 

shock. 

 

Cleaning 

• 

Power off and unplug the unit before any cleaning. 

• 

Clean the housing with a soft damp cloth. Do not use chemical solvent (such as benzene, alcohol, 

gasoline). The surface may become damaged or deformed. 

• 

Do not sprinkle water on the unit. 

 

 

Air filter 

• 

Clean the air filter every 2 weeks. If the air filter is   

blocked with dust, the efficiency will be reduced.   

• 

Open the air filter cover upwards, then take out the air 

filter. 

• 

Wash the air filter by immersing it gently into warm 

water with a neutral detergent, rinse it and dry 

it thoroughly in a shaded area. 

 

 

End of season 

• 

Uncap the lid; remove the rubber plug on the drainage hole   

to drain the water. 

• 

Keep the unit running in fan mode for several hours 

until the inside of the unit is dry. 

• 

Turn off the unit and unplug it,

 

screw the lid up.   

• 

Take out the batteries of the remote control and keep them. 

• 

Clean the air filter and reinstall it. 

• 

Remove the air hoses and keep them in a safe place.   

• 

Wrap the unit with plastic and keep it in a dry place. 

• 

Make sure the unit is completely dry before storing to avoid a mould smell. 

 

Control and Safety of Electrical Control Board 

• 

FL Protection (Water-full protection, to prevent spilling). 

• 

E1, E2, sensor protection, to avoid occurrence of unit damage, auto-stop protection. 

• 

E3, unit-abnormal protection, to avoid occurrence of unit damage. 

 

Evaporator Defrosting 

• 

When the coil sensor feels a temperature of less than 2°, the unit will stop and display E4 to defrost, 

and the fan speed will be low. 

• 

When the coil temperature runs up to 8°+, the unit will re-cool.   

 

Содержание PPAC15

Страница 1: ...15 000 BTU PORTABLE AIR CONDITIONER Model PPAC15 User Manual READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...1 CONTENTS IMPORTANT SAFEGUARDS 2 INSTALLATION 4 IDENTIFICATION 6 CONTROL PANEL 7 REMOTE CONTROL 8 OPERATION 9 WATER DRAINAGE 10 MAINTENANCE 11 TROUBLESHOOTING 12 ...

Страница 3: ...ntended use Do not operate this product with a damaged cord or plug or after the product malfunctions or appears damaged in any way If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard This appliance is for indoor use only Keep the appliance away from heat sources and direct sunlight Never insert finge...

Страница 4: ...imum distance from furniture and walls is 50cm in all directions The plug should be easily accessible In order to maintain the function of the compressor the appliance should always be in a vertical position Do not use the appliance near gas or other flammable liquids Do not block the air outlet or the air inlet ventilation Do not use spray insecticides paint or any other flammable products near t...

Страница 5: ...minal of the unit 2 Half open the window and let the air outlet duct through The window slider kit has been designed to fit most standard vertical and horizontal windows It is adjustable Permanent method 1 Fix the end of the exhaust duct to the exhaust terminal of the unit 2 Cut hole Φ155mm into the wall 3 Fit the supplied round exhaust on the air outlet duct Mounting in the wall ...

Страница 6: ...ir must be able to flow freely WARNING The length of the exhaust pipe is specifically designed according to the specification of this product Do not replace or lengthen it with your own private hose as this could cause mal function CAUTION Use the shortest possible length When mounting we advise to keep the exhaust pipe in a horizontal position When the hole is not in use use the cap to cover the ...

Страница 7: ...Back 6 Castor 7 Air inlet 8 Drain port used when there is continuous drainage or in dry mode 9 Power cord 10 Drain port used when the water tank is full or hasn t been used in a long time Check all the accessories included in the package and please refer to the installation instructions for their use Accessories ...

Страница 8: ...ton press this button to select high middle or low fan speed 4 TIMER button press this button to set timer on timer off or no timer 5 UP DOWN button press these buttons to set room temperature or timer when in Time On Off mode 6 LCD display display different signals accordingly Note To choose from Fahrenheit or Celsius press both UP and DOWN button ...

Страница 9: ...n speed button 2 Middle fan speed button 3 Low fan speed button 4 Swing button 5 Timer button 6 Up button 7 Down button 8 Cool mode button 9 Dry mode button 11 Celsius and Fahrenheit button 12 Power button same as ON OFF button ...

Страница 10: ...utlet duct Dry mode will not cool the room Fan mode Press MODE button or Fan button to choose Fan mode the LCD will display Select the fan speed by pressing the SPEED button or High Mid Low button directly Press the Swing button to make the louvres swing use remote control only The LCD will display The temperature cannot be set Do not use the air outlet duct Timer on When the appliance is switched...

Страница 11: ...ter drainage During dehumidifying mode remove the drain plug from the back of the unit then install a drain hose φ10mm inner dimension and place the open end of the hose into any vessel such as a bucket If the internal water container is full the LCD display will flash FL and the unit will stop automatically Note If the water full alarm is often on the unit may malfunction Contact a professional s...

Страница 12: ...g on the drainage hole to drain the water Keep the unit running in fan mode for several hours until the inside of the unit is dry Turn off the unit and unplug it screw the lid up Take out the batteries of the remote control and keep them Clean the air filter and reinstall it Remove the air hoses and keep them in a safe place Wrap the unit with plastic and keep it in a dry place Make sure the unit ...

Страница 13: ...brations The compressor does not work The overheat protection is probably activated Wait 3 minutes until the temperature has decreased then turn on the unit again The remote control does not function Distance is too great Make sure the remote control is correctly aimed at the control panel Remote control signal not detected by the control panel The batteries are drained Replace the batteries Cauti...

Отзывы: