1-10-1
E9A12FIS
FUNCTION INDICATOR SYMBOLS
< VCR Section >
Note:
If a mechanical malfunction occurs, the power is turned off. When the power comes on again after that by
pressing [STANDBY-ON] button, an error message is displayed on the TV screen for 5 seconds.
TV screen
When reel or capstan mechanism is not functioning
correctly
When tape loading mechanism is not functioning cor-
rectly
When cassette loading mechanism is not functioning
correctly
When the drum is not working properly
P-ON+5V Power safety detection
Led Mode
Indicator Active
When reel or capstan mechanism is not
functioning correctly
“
A
R” is displayed on a TV screen. (Refer to Fig. 1.)
When tape loading mechanism is not
functioning correctly
“
A
T” is displayed on a TV screen. (Refer to Fig. 2.)
When cassette loading mechanism is not
functioning correctly
“
A
C” is displayed on a TV screen. (Refer to Fig. 3.)
When the drum is not working properly
“
A
D” is displayed on a TV screen. (Refer to Fig. 4.)
P-ON+5V Power safety detection
“
A
P” is displayed on a TV screen. (Refer to Fig. 5.)
A
R
SP 0:00:00
Fig. 1
A
T
SP 0:00:00
Fig. 2
A
C
SP 0:00:00
Fig. 3
A
D
SP 0:00:00
Fig. 4
A
P
SP 0:00:00
Fig. 5
Содержание PY90VG
Страница 37: ...1 12 3 Main 1 7 Schematic Diagram VCR Section E9A12SCM1 ...
Страница 39: ...1 12 5 Main 3 7 Schematic Diagram VCR Section E9A12SCM3 ...
Страница 40: ...1 12 6 Main 4 7 Schematic Diagram VCR Section E9A12SCM4 ...
Страница 41: ...1 12 7 Main 5 7 Schematic Diagram VCR Section E9A12SCM5 ...
Страница 42: ...1 12 8 Main 6 7 Schematic Diagram VCR Section E9A12SCM6 ...
Страница 43: ...1 12 9 Main 7 7 Schematic Diagram VCR Section E9A12SCM7 ...
Страница 45: ...1 12 11 Front Jack Schematic Diagram VCR Section E9A12SCJK ...
Страница 74: ...1 18 2 E9A12PEX Packing S1 A14 S2 S2 S2 Unit S3 Some Ref Numbers are not in sequence X1 X22 X4 X20 X5 X2 X3 S2 ...
Страница 83: ...PY90VG E9A12UD 2006 06 15 ...