PXM Splitter DMX-RDM Скачать руководство пользователя страница 3

1. 

GENERAL INFORMATION

3

DMX-RDM signal splitter

This  signal  splitting  device,  or  DMX-RDM  splitter,  allows  for  providing  branches  in  extensive 

DMX-RDM  installations. As  connecting  multiple,  series-connected  receivers  to  form  a  single 

chain can be difficult, provision has been made in the design of the splitter to create DMX-RDM 

line branches. Moreover, the PX716 will amplify and regenerate RDM-DMX signal, removing 

interference effects, as well as eliminating signal reflections on DMX-RDM lines.

The PX716 will split an input DMX-RDM signal into 4 independent branches. Galvanic isolation is 

provided between individual outputs themselves as well as from the input, and the outputs are 

adequately  amplified,  which  ensures  proper  operation  of  the  entire  installation.  The  PX716 

supports  the  RDM  protocol.  A  maximum  of  four  splitters  can  be  connected  in  a  cascading 

arrangement.

The PX716 splitter has a metal housing. Additional mounting kits are available for installing a 

single PX716 unit in a RACK system, two units side by side in a RACK system, or for suspending 

a PX716 from e.g. a truss.

The PX716 is designed to run from 230 V AC mains.

2. 

SAFETY CONSIDERATIONS

The PX716 is a device powered directly from power grid 230 V, what may result in electric shock  

in case of not following safety rules. During its installation and use the following rules must be 

strictly observed:

1. Installation of the device should be carried out by a person with appropriate qualifications in 

accordance with this document.

2. The electrical outlet to which the switch is connected have to be linked to a working protective 

installation (3-wire installation.)

3. Protect the power cord from mechanical and thermal damage.

4. In  case  of  damage  the  power  cord,  cable,  replace  it  with  the  same  technical  data  and 

certificates.

5. For connecting devices to the Splitter use only 3-wire cables with cross-section of not less 

than 1.5 mm.

6. Connection of DMX signal can only be made with shielded conductor.
7. All repairs and connections of outputs or DMX signal can only be made with cut off power 

supply.

8. PX716 should be strictly protected against contact with water and other liquids.
9. All sudden shocks, particularly dropping, should be avoided.
10. The device cannot be turned on in places with humidity exceeding 80%.

o

o

11. The device cannot be used in places with temperature lower than 2 C or higher than 40 C. 
12. Clean it with damp duster only.