Safety conditions
PX815 is a device powered by 12 – 24V DC safety voltage, however,
during its installation and use 230V AC voltage may be used, which may result
in electric shock if the safety rules are not followed. The following rules must
be strictly observed:
1. The device may only be connected to 12 – 24V DC with current-
carrying capacity compatible with technical data.
2. All the conductors should be protected against mechanical and
thermal damage.
3. In the event of damaging any conductor, it should be replaced with a
conductor of the same technical data.
4. Connection of DMX signal can only be made with shielded conductor.
5. All repairs and connections of outputs or DMX signal can only be
made with cut off power supply.
6. The PX815 should be strictly protected against contact with water and
other liquids.
7. To connect the control outputs, use only cables with a cross-section
of at least 2.5mm
2
.
8. All sudden shocks, particularly dropping, should be avoided.
9. Do not connect the device with a damaged (broken) housing to the
power supply
10. The device cannot be turned on in places with humidity exceeding
90%.