8

RDM – available parameters

The PX801-T supports the DMX-RDM protocol. DMX protocol allows only 

of a one-way data transmission, while extension the RDM protocol can 
transmit information in two directions. This makes possibility of monitoring 
activities of the compatible devices. Thanks to RDM some available settings 
of compatible devices may be programmed using this protocol.
List of RDM parameters supported by the PX

 

 801-T

 

 :  

Parameter name

PiD

Description

SUPPORTED_PARAMETERS

0x0050 all supported parameters

PARAMETER_DESCRIPTION 0x0051 description of additional 

parameters

DEVICE_INFO

0x0060 information concerning the device

SOFTWARE_VERSION_LABEL 0x00C0 firmware version of the device
DMX_ADDRESS *

0x00F0 DMX starting address of the device

IDENTIFY *

0x1000

device identification;

Two states are possible: 

identification is off (0x00 value) 

and identification is on (0x01 value)

DEV_MODEL_

DESC

0x0080 device description, e.g. name

MANUFACTURER_LABEL

0x0081 manufacturer description,

e.g. name

DEVICE_LABEL *

0x0082

additional device description;

It is possible to enter an additional 

device description using up to 32 

ASCII characters

14

Содержание PX801-T

Страница 1: ...PX801 T PxArt 06 Mono Track PxArt 12 Mono Track PxArt 18 Mono Track User manual...

Страница 2: ...6 2 DMX signal 10 7 Cooperating with the PX277 configurator 11 7 1 Available parameters 11 7 2 Scheme of the PX801 T menu in PX277 13 8 RDM available parameters 14 9 Connection scheme 16 10 Dimensions...

Страница 3: ...is devoid of the effect of light vibration flicker free technology in the full control range which makes it useful in the television industry The device features a base which allows for mounting it in...

Страница 4: ...s Warning Read the instruction manual Caution Do not look at the LEDs LEDs can cause damage or eye irritation Do not look at the light source with any optical devices that focus the light rays Light i...

Страница 5: ...d must meet the safety requirements the installation must be 3 wire and equipped with a residual current device 3 All the conductors should be protected against mechanical and thermal damage 4 In the...

Страница 6: ...3 Connectors and control elements 6 PX277 parameter programming connector Brightness adjustment...

Страница 7: ...e 10 10 20 20 30 30 40 40 EL elliptical lenses WW Wall Washer YYY CRI and color temperature 927 CRI 90 temp 2700K 930 CRI 90 temp 3000K 935 CRI 90 temp 3500K 945 CRI 90 temp 4500K Z housing colors 1 g...

Страница 8: ...5 1 GLOBAL Trac GAC 600 adapter 5 2 The cross section of the DMX GLOBAL Trac Pulse Control 8 DMX contacts MAINS POWER SUPPLY neutral on the opposite side phase 3 phase selection switch phase 1 on the...

Страница 9: ...n case of the loss of DMX signal diode lights continuously for 1 minute if the state of DMX signal changed if there wan no DMX signal and it returned or vice versa diode signals it for 1 minute damage...

Страница 10: ...decrease While the lamp operates the diode stays switched off excluding situations mentioned above 6 2 DMX signal The PX801 T lamp can be controlled via DMX channels Channel 1 brightness Setting the l...

Страница 11: ...parameters DMX Addr changing the DMX address of the brightness channel in the range 1 512 No Signal behavior of the device when the DMX signal disappears Scene setting the scene displayed when the DMX...

Страница 12: ...dule with LEDs PWR time ACT time total lamp operation time total lamp lighting time Factory Default factory reset in PX801 T DMX Addr 001 No Signal Off Scene 128 No Signal Time 1 0 s Smooth Level 3 Co...

Страница 13: ...Signal Time 0 0 s No Signal Time 1 0 s NEXT No Signal Time 10 0 s ENTER No Signal Time 1 0 s NEXT Smooth Off NEXT ENTER NEXT Control Mode 1ch MONO NEXT Smooth Off Smooth Level 1 NEXT Smooth Level 4 Co...

Страница 14: ..._PARAMETERS 0x0050 all supported parameters PARAMETER_DESCRIPTION 0x0051 description of additional parameters DEVICE_INFO 0x0060 information concerning the device SOFTWARE_VERSION_LABEL 0x00C0 firmwar...

Страница 15: ...information on the selected temperature sensor SENSOR_VALUE 0x0201 information about sensors SMOOTH_OFF 1 2 3 4 0x801A selection of smoothing options NO_SIGNAL_OFF ON HLD S 0x801C behavior of the dev...

Страница 16: ...9 Connection scheme 16 3 phase GLOBAL Trac Pulse Control bus bar end feed power supply cable DMX wire 2 wires in screen GLOBAL Trac GAC600 adapter DMX DMX GND...

Страница 17: ...10 Dimensions PxArt 06 Mono Track PxArt 12 Mono Track 92 134 225 284 17...

Страница 18: ...data type PX801 T power supply 230V AC number of diodes 6 12 18 power consumption PX801 T 06 10W PX801 T 12 17 5W PX801 T 18 25W max temperature rise housing 30 C LEDs lifespan 50000h beam angle 10 20...

Страница 19: ...PX801 T 12 1 7kg PX801 T 18 2 4kg dimensions height PX801 T 06 225mm diameter PX801 T 06 92mm height PX801 T 12 235mm diameter PX801 T 12 122mm height PX801 T 18 252mm diameter PX801 T 18 148mm not av...

Страница 20: ...ing directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Te...

Отзывы: