background image

Parameter name

PiD

Description

FACTORY_DEFAULTS

0x0090 device default settings

PERSONALITY *

0x00E0 DMX operational mode

PERSONALITY_

DESCRIPTION

0x00E1 description of individual 

operational modes

SENSOR_DEFINITION

0x0200 information on the selected 

temperature sensor

SENSOR_VALUE

0x0201 information about sensors

SMOOTH_OFF/1/2/3/4 *

0x801A selection of smoothing options

NO_SIGNAL_OFF/ON/HLD/S 

*

0x801C behavior of the device when the 

DMX signal disappears

NOS_TIME *

0x804D device reaction time when DMX 

signal disappears (0 – 10s)

NOS_SCENE_1 *

0x8021 setting channel 1 in the scene

NOS_SCENE_2 *

0x8022 setting channel 2 in the scene

SERIAL_NUMBER

0x8030 device serial number

* - editable parameter

15

Содержание PX800-T

Страница 1: ...PX800 T PxArt 06 Track PxArt 12 Track PxArt 18 Track User manual...

Страница 2: ...6 2 DMX signal 10 7 Cooperating with the PX277 configurator 11 7 1 Available parameters 11 7 2 Scheme of the PX800 T menu in PX277 13 8 RDM available parameters 14 9 Connection scheme 16 10 Dimensions...

Страница 3: ...a lamp that is devoid of the effect of light vibration flicker free technology in the full control range which makes it useful in the television industry The device features a base which allows for m...

Страница 4: ...s Warning Read the instruction manual Caution Do not look at the LEDs LEDs can cause damage or eye irritation Do not look at the light source with any optical devices that focus the light rays Light i...

Страница 5: ...d must meet the safety requirements the installation must be 3 wire and equipped with a residual current device 3 All the conductors should be protected against mechanical and thermal damage 4 In the...

Страница 6: ...AA XX Z AA version 06 6 LEDs 12 12 LEDs 18 18 LEDs XX beam angle 10 10 20 20 30 30 40 40 EL elliptical lenses WW Wall Washer Z housing colors 1 gray 2 black 3 white not available for the PX800 T 06 la...

Страница 7: ...5 1 GLOBAL Trac GAC 600 adapter 5 2 The cross section of the DMX GLOBAL Trac Pulse Control 7 DMX contacts MAINS POWER SUPPLY neutral on the opposite side phase 3 phase selection switch phase 1 on the...

Страница 8: ...ess adjustment button 1Hz frequency in the first minute after receiving the DMX signal after the start of the lamp in case of the loss of DMX signal diode lights continuously for 1 minute if the state...

Страница 9: ...rightness is increased release the control button for a moment The diode will signal the change of adjustment direction The pressing of the adjustment button again will cause the dimming of the lamp b...

Страница 10: ...led via two DMX channels Channel 1 color Channel 2 brightness Setting the lamp parameters Value of the lamp parameter Value of the DMX signal Adjusting the color temperature 4500K 255 3600K 128 2700K...

Страница 11: ...DMX address of the color temperature and brightness channel in the range 1 512 No Signal behavior of the device when the DMX signal disappears Scene setting the scene displayed when the DMX signal di...

Страница 12: ...t and current operating temperature of the module with LEDs PWR time ACT time total lamp operation time total lamp lighting time Factory Default factory reset in PX800 T DMX Addr 001 No Signal Off Sce...

Страница 13: ...nal Hold Channel 1 Value 128 NEXT Channel 1 Value 255 Channel 1 Value 128 NEXT Channel 2 Value 128 ENTER PREV No Signal Time 0 0 s No Signal Time 1 0 s NEXT No Signal Time 10 0 s ENTER No Signal Time...

Страница 14: ..._PARAMETERS 0x0050 all supported parameters PARAMETER_DESCRIPTION 0x0051 description of additional parameters DEVICE_INFO 0x0060 information concerning the device SOFTWARE_VERSION_LABEL 0x00C0 firmwar...

Страница 15: ...ted temperature sensor SENSOR_VALUE 0x0201 information about sensors SMOOTH_OFF 1 2 3 4 0x801A selection of smoothing options NO_SIGNAL_OFF ON HLD S 0x801C behavior of the device when the DMX signal d...

Страница 16: ...9 Connection scheme 16 3 phase GLOBAL Trac Pulse Control bus bar end feed power supply cable DMX wire 2 wires in screen GLOBAL Trac GAC600 adapter DMX DMX GND...

Страница 17: ...10 Dimensions PxArt 06 Track PxArt 12 Track 92 134 225 284 17...

Страница 18: ...chnical data type PX800 T power supply 230V AC number of diodes 6 12 18 power consumption PX800 T 06 10W PX800 T 12 17 5W PX800 T 18 25W max temperature rise housing 30 C luminous flux PX800 T 06 600l...

Страница 19: ...ors gray black white weight PX800 T 06 1 3kg PX800 T 12 1 7kg PX800 T 18 2 4kg dimensions height PX800 T 06 225mm diameter PX800 T 06 92mm height PX800 T 12 235mm diameter PX800 T 12 122mm height PX80...

Страница 20: ...g directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Text...

Отзывы: