Parameter name
PiD
Description
MANUFACTURER_LABEL
0x0081 manufacturer description,
e.g. name
DISPLAY_FLIP *
0x8031 inverting the meter display 180
degrees
DEVICE_LABEL *
0x0082
additional device description;
It is possible to enter an additional
device description using up to
32 ASCII characters.
DMX_PERSONALITY
0x00E0 DMX operational mode
DMX_PERSONALITY_
DESCRIPTION
0x00E1 description of individual
operational modes
DEVICE_HOURS
0x0400 operating time counted in hours
TEMPERATURE_LIMIT_
ON/OFF *
0x800E
temperature limitation activation
for the temperature sensor
connected to the driver
TEMPERATURE_
THRESHOLD_LOW *
0x800F
lower temperature value for which
the temperature limitation is being
activated
TEMPERATURE_
THRESHOLD_HIGH *
0x8010
upper temperature value for which
the temperature limitation is active,
i.e. the cut-off temperature for exits
from the driver
BALANCE_RED *
0x8011 value of control level of red channel
balance
BALANCE_GREEN *
0x8012 value of control level of green
channel balance
BALANCE_BLUE *
0x8013 value of control level of blue
channel balance
BALANCE_WHITE *
0x8014 value of control level of white
channel balance
28
Содержание PX714