PXM PX390 Скачать руководство пользователя страница 1

MANUAL

PX390

PxArt+ 6

R

Содержание PX390

Страница 1: ...MANUAL PX390 PxArt 6 R ...

Страница 2: ...ngs 6 2 7 Response to the lack of DMX signal 7 DMX signal and power supply connection 7 1 GLOBAL Trac GAC 600 adapter 7 2 Section through the DMX bus duct 8 RDM description of available parameters 9 Device programming 10 Dimensions 11 Technical data Declaration of conformity 3 3 5 6 7 8 9 9 9 10 10 11 11 11 12 13 13 13 14 16 17 18 19 Manufacturer reserves the right to make modifications in order t...

Страница 3: ...ght sources and advanced control electronics a high class illuminator was created which meets very high requirements for museum and exhibition lighting Its most important advantages include a complete lack of ultraviolet radiation emission trace amounts of infrared radiation a very high factor of CRI colour capturing smooth adjustment of colour temperature of emitted light large brightness and sma...

Страница 4: ... technical parameters 5 All repairs can only be carried out with power disconnected 6 The device with visible mechanical damage cannot be connected to the mains 7 Avoid sudden shocks particularly dropping 8 The device must not be used in rooms with a temperature below 2 C or above 40 C 9 Clean only with a damp cloth the lamp must be at this time completely disconnected from the power supply In cas...

Страница 5: ...ur 1 grey 2 black 3 white Example of lamp designation PX390 20 MW 1 3 VERSION DATA 5 Lamp catalogue number The reflector angle 20 Colour of applied LEDs dynamic white Lamp housing colour grey The dimming of the lamp brightness occurs when the temperature is above 70 C this prevents the device from overheating If the device reaches a temperature of 90 C the power of the lamp will be totally reduced...

Страница 6: ...4 LAMP DESCRIPTION 6 o 360 1 3 4 5 1 2 3 4 a 3 phase track for GLOBAL Trac Pulse control 2 end feed power cable DMX cable shielded cable 2 core cable GLOBAL Trac GAC 600 adapter 5 DMX DMX GND ...

Страница 7: ...For example while the lamp brightness is increased release the control button for a moment The diode will signal the change of adjustment direction The pressing of the adjustment button again will cause the dimming of the lamp brightness decrease While the lamp operates the diode stays switched off excluding situations mentioned above For lamps with RGB LEDs configuration programming buttons avail...

Страница 8: ...without switching the diodes off Additionally information concerning minimum maximum and current temperature reached by the lamp is displayed PxArt Settings Controller also allows for checking the version number of the software which is installed in the lamp its serial number and model Navigating through the menu is possible with programmer buttons located below the display The escape button allow...

Страница 9: ...are installed in the PX390 lamp Lamp model Information concerning the minimum maximum and current temperature reached by the lamp Aunit expressed in C 6 2 Setting lamp parameters 6 2 1 Lamp color and brightness address PX277 allows for changing the DMX address which controls the color and brightness of the lamp The lamp has the DMX channel assigned whose value can be changed depending on the needs...

Страница 10: ...rpretation according to the scheme Value 0 Value 255 Warm white Cold white SWITCHING ON THE FUNCTION Invert color Value 0 Value 255 Cold white Warm white 6 2 3 Flicker Free Flicker free On Flicker free On ENTER Flicker free Off NEXT Model PX390 6 MW 6x NEXT The Flicker free technology allows for avoiding an unpleasant flickering of light during video recording Bright address 001 Bright address 001...

Страница 11: ...for changing the smoothing time value As a result it enables an acceleration or deceleration of the brightness and colour parameter change Maximum available value is 2000 ms and minimum is 10 ms makes it possible to change the time parameter at which subsequent different DMX signal values sent to the lamp are smoothed among themselves The user may set the smoothing time using previous and next but...

Страница 12: ...ange of scene colour and brightness is possible directly from the lamp buttons or with the use of PX277 These values can be set between 0 and 255 Scene bright 000 ENTER Scene bright 255 NEXT Scene bright 128 Scene color if set to 0 changes the colour temperature value of the lamp to warm and 255 to cold 128 sets the neutral colour temperature Values between the above values correspond to the colou...

Страница 13: ...X GLOBAL Trac Pulse control bus duct 4 3 1 2 6 5 7 7 1 2 3 4 5 6 phase 3 phase 1 phase 2 neutral DMX GND DMX POWER DMX 5 1 2 3 4 DMX CONTACTS POWER CONTACTS neutral phase 3 on the opposite side phase selector switch phase 1 phase 2 on the opposite side earth 2 3 4 5 1 DMX on the opposite side DMX 3 1 2 ...

Страница 14: ...2 According to the RDM standard for device whose footprint is 0 the value of this parameter may be 65535 and then it is not possible to change the initial address settings for the entire device but only for sub devices IDENTIFY_DEVICE 0x1000 device identification Two states are possible identification is off 0x00 value and identification is on 0x01 value DEVICE_MODEL_ DESCRIPTION 0x0080 device des...

Страница 15: ...acket mode P2P and for 2 value the smooth function operates in the time mode Value 0 set by default smoothing off SMOOTH_TIME 0x801B smoothing time for TIM time function selected in the above point Unit expressed in ms Minimum parameter value is 10 and maximum is 2000 ms Default value is 200 ms SCENE_COLOR 0x8021 color temperature settings Minimum value 0 maximum value 255 Default value is 128 SCE...

Страница 16: ...cene bright 000 Scene bright 255 NEXT ENTER Smooth Off Smooth P2P NEXT Smooth Time NEXT ENTER Smooth time 0010 ms Smooth time 2000 ms NEXT Default sett PREV NEXT 2s PREV NEXT Default sett Reset OK ENTER ENTER NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT Color address 001 NEXT Color address 001 Color address 512 NEXT ENTER Scene color 128 NEXT Scene color 001 Scene color 255 NEXT ENTER Invert ...

Страница 17: ...10 DIMENSIONS 17 Ø 92 134 225 283 5 Dimensions are given in millimetres ...

Страница 18: ...mperature Brightness regulation extension CRI colour rendering index CRI Control protocol Available housing colours Weight Dimensions 230 V AC 6 10 W 30 C 600 lumens 50 000 h 10 20 30 40 EL 2700 4500 K 0 100 min 90 DMX 512 RDM Silver black white 1 3 kg Width 134 mm Height 225 mm Diameter of the reflector 92 mm Spectral characteristics of the emitted light ...

Страница 19: ...sing a shielded cable connected to the GND pin mgr inż Marek Żupnik Name of producer Address of producer declares that the product Name of product Type answers the following product specifications LVD EMC Additional informations Kraków 18 05 2015 DECLARATION OF CONFORMITY according to guide lines 2004 108 WE and 2006 95 WE tel 12 626 46 92 fax 12 626 46 94 e mail info pxm pl http www pxm pl ul Prz...

Отзывы: