To do this, confirm the
Default settings
by pressing
enter
, then select the
Yes
button and confirm by pressing
enter
again. If this option is selected by
mistake, exit the menu by selecting the
No
button or directly by pressing the
escape
button.
7
DMX signal connecting
PX252 have to be connected to DMX line in serial mode, with no branches
on DMX control cable. That means that DMX line, from the signal source,
must be connected to
DMX IN
pins of PX252 and later, directly from
DMX OUT
pins to the next device in DMX chain.
If the PX252 is the last DMX chain receiver there should be terminator
(resistor 120 Ohm) mounted between “
DMX+
" and “
DMX-
" pins of
DMX OUT
section.
DMX IN
DMX OUT
-
-
+
+
GND
GND
CORRECT
DMX-512 input
DMX-512 output
DMX IN
DMX OUT
-
-
+
+
GND
GND
WRONG
DMX-512 line
DMX IN
DMX OUT
-
-
+
+
GND
GND
TERMINATOR CONNECTION
DMX-512 input
120 Ohm