PXM Mirage RedLine II Скачать руководство пользователя страница 3

1. GENERAL DESCRIPTION

1

ATTENTION:

2. SAFETY CONDITIONS

PX126 Mirage RedLine is powered 

from standard 230 V grid, what can cause electric 

shock when safety rules are not observed. Therefore it is necessary to observe the following:

1. The device can be connected to the mains through the enclosed power cable only.

2. Controller can be connected to socket which has protecting instalation in working order (3 - 

wire grid) only.

3. All the conductors should be protected against mechanical and thermal damage.

4. In the event of damaging any conductor, it should be replaced with a conductor of the same 

technical data and attestations.

5. All repairs demanding casing opening should be made with cut off power supply.

6. Controller should be strictly protected against contact with water and other liquids.

7. All sudden shocks, particularly dropping, should be avoided.

8. Device with damaged (cracked) casing should not be connected to the mains.

9. The device cannot be turned on in places with humidity exceeding 90%.

o

o

10. The device cannot be used in places with temperature lower than 2 C or higher than 40 C.

11. Cleaning with damp duster only - PX126 has to be cut off the power supply.

directly 

For user comfort two modes of "moved slider" are available:
1. "10%" - the programmed device starts to react when the control slider has been moved for at 

least 6 milimeters.

2. "interception" - the programmed device starts to react when the control slider's value exceeds 

(regardless of the direction) the programmed value for the particular DMX channel.

For the description of selection of sliders' reaction mode see page 13.

PX126 Mirage 

RedLine II 

is a versatile DMX controller for scanners, stage lighting or advertising 

lighting installations control. With PX126 the user can control any device compatible with the 

DMX-512 standard, as the dimmers, smoke generators, colours' changers, central effects or 

scanners and heads, for which the controller is mainly intended.

Mirage RL controls 256 DMX channels, that are divided into sixteen 16-channel groups. In a 

single group the user can control one 16-channel device or a few devices, that are controlled 

through lower number of DMX channels (eg. sixteen 1-channel dimmers).

As for the programming, the controller allows to define 48 programs, consisting of up to 1022 

scenes.  The  entirely  new  feature  is  the  possibility  of  simultaneous  rendering  of  up  to  three 

programs  with  the  different  speeds.  The  maintenance  comfort  is  extended  by  the  maximal 

simplification of programs' saving and rendering processes.

By dint of RS-232 interface the Mirage controller can be connected to the PC computer.

Содержание Mirage RedLine II

Страница 1: ...INSTRUCTION MANUAL Mirage RedLine II PX126 R...

Страница 2: ...deletion 7 Programs rendering 7 1 One program rendering start 7 2 Another program rendering start 7 3 Program rendering stop 8 Collections CUEs rendering 9 Special keys 9 1 Manual control 10 Blackout...

Страница 3: ...modes of moved slider are available 1 10 the programmed device starts to react when the control slider has been moved for at least 6 milimeters 2 interception the programmed device starts to react wh...

Страница 4: ...ect output to the third effect input etc 4 The terminator must be installed in the last device s DMX output socket nd rd XLR plug with the 110 Ohm resistor between 2 and 3 pin installed 5 Set the DMX...

Страница 5: ...LOAD starts rendering the selected program 2 DMX CHANNELS CONFIGURATION BLOCK 1 DEVICE SELECTION BLOCK Set of 16 keys for controlled device selection The key activity status is indicated by an appropr...

Страница 6: ...ppropriate scanner the corresponding LED will light up You can choose a few scanners at the same time if they are of the same kind only In such case the settings eg GOBOs or colours will be changed on...

Страница 7: ...ing program rendering particular scenes are rendered according to the programmed order The memory is divided in such a way as it assigns a different numbers of steps to the programs but you can merge...

Страница 8: ...ge synchronization 2 Press the LOAD PROGRAM key 3 In theTRIGGERING block select a required synchronization mode 4 If you select AUTO adjust speed and step to step fading smoothness with the SPEED and...

Страница 9: ...ING block is lit turn it off by pressing the corresponding key 3 With and keys select the scene you want to be launched with one of the special keys 4 Press the SAVE key and after that the selected ke...

Страница 10: ...his key an automatic dimming of all the other devices BLACKOUT until this key is released To turn this feature on 1 By pressing the appropriate key eg EXTRA check if that causes BLACKOUT If not go to...

Страница 11: ...MING The Mirage controller interprets the MIDI signals according to the standard You must pay attention to the fact that some of the MIDI instruments carry the MIDI communication out according to the...

Страница 12: ...OGRAMS display where the decimal dots are visible 1 Switch BLACKOUT off 2 With and keys select the program number you want to render In the LOAD PROGRAM key the LED will light up that means the contro...

Страница 13: ...ticular devices operation After selecting the device in the SCANNER block you can change its settings with the sliders the selected device responds to the changes in the channels where the sliders hav...

Страница 14: ...e exe application on your PC PC application SPEED PC SPEED PC 12 FROM SOLO RL CONTROLLER PROGRAMS COPYING 1 Connect the Mirage RLand Solo RLcontrollers with the programming cable both devices have to...

Страница 15: ...ion Change of reaction to slider movement requires the appropriate FirmWare installation 10 reaction all FirmWare versions ended with an odd number interception reaction All FirmWare versions ended wi...

Страница 16: ...ntroller programming AUDIO IN 775 mV MAINS 230V 50Hz POWER RS 232 DMX OUT SOLO LINK SERIAL No PRODUCT No PX111 MIDI IN THRU www proxima eu female female PUSH ATTENTION If such a communicate is display...

Страница 17: ...XLR socket 5 pin DIN socket 9 pin D SUB socket telephone socket 230 V 50 Hz 6 VA 2 kg 520 mm 210 mm 80 mm DMX channels scenes programs collections CUEs inputs audio 0 dB MIDI RS 232 for Solo controlle...

Страница 18: ...cient ground installation Name of producer Address of producer declares that the product Name of product Type answers the following product specifications LVD EMC Additional informations Krak w 01 06...

Отзывы: