background image

PX788

Merger DMX 3/1

User manual

Содержание Merger DMX 3/1

Страница 1: ...PX788 Merger DMX 3 1 User manual...

Страница 2: ...he device 16 4 5 3 Restore default settings 17 4 6 Setting the display contrast 18 4 7 Menu scheme in PX788 19 5 Connecting the merger with a PC 20 5 1 Change of the computer network configuration 21...

Страница 3: ...11 Dimensions 43 12 Technical data 43 Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek upnik sp k Pod e 654 32 003 Pod e BDO register number 000005...

Страница 4: ...a single DMX output Merger can operate in two configurations 3 1 2 2 it means that the device can sum up 3 inputs and send the result DMX signal to one line or sum 2 inputs and send the result signal...

Страница 5: ...conductor it should be replaced with a conductor of the same technical data 4 Connection of DMX signal can only be made with shielded conductor 5 All repairs and connections of outputs or DMX signal c...

Страница 6: ...3 Connectors and control elements 6 PX788 Merger DMX 3 1 programming keyes display signaling diodes Ethernet port power supply 12 24V DC DMX 512 connectors PX788 DMX Merger 192 168 1 150...

Страница 7: ...g set enter allows to enter the programming mode and confirm the values set If the parameter is editable then in the lower right corner there is an edit symbol while causes the transition to the editi...

Страница 8: ...ddress of the device 4 3 DMX settings 4 3 1 Output channels In the DMX outputs menu you can set parameters for the DMX output Depending on the Mode setting one 3 1 or two 2 2 DMX outputs are available...

Страница 9: ...the input is equal to the current value at the output the given input takes control over the output calculated for each channel separately Mixed merging between input 2 and 3 and between this result a...

Страница 10: ...ty for the output if there is a signal on it e g 1 2 the signal from input 1 is sent if the signal from input 1 is lost the signal from input 2 is sent for 2 2 mode 1 2 2 1 for 3 1 mode 1 2 3 1 3 2 2...

Страница 11: ...mode LTP Priority 1 2 3 NEXT Mixed A B C Input affinity 1 2 3 ENTER Input affinity 1 2 3 NEXT Input affinity 1 3 2 NEXT Input affinity 2 1 3 NEXT Input affinity 2 3 1 NEXT Input affinity 3 1 2 NEXT In...

Страница 12: ...et in the range 1 512 this parameter cannot be set to a value lower than in Input start Output start starting DMX address on the output to which the channels are to be sent set in the range 1 512 No s...

Страница 13: ...t start bit range 0 s 76 s 13 ENTER PX788 DMX Merger 192 168 1 150 DMX outputs NEXT Mode 3 1 ENTER DMX output 1 NEXT DMX output 2 ENTER Channels number 512 2 x NEXT Input 1 1 1 ENTER ENTER Input start...

Страница 14: ...TER PX788 DMX Merger 192 168 1 150 DMX outputs NEXT Mode 3 1 ENTER DMX output 1 NEXT DMX output 2 ENTER Channels number 512 4 5 xNEXT DMX timings ENTER Break time us 176 PREV Break time us 352 MBF tim...

Страница 15: ...network configuration from DHCP server 4 5 Other parameters The menu containing the other settings Management allows to turn on On or turn off Off the screen and the indicator lights Dark mode restart...

Страница 16: ...2 Reboot the device Reboot device is available which should be used after making network changes to the device using the built in LCD display and buttons 16 ENTER PX788 DMX Merger 192 168 1 150 Menage...

Страница 17: ...de 2 2 Channels number 512 Merging mode HTP Input 1 2 3 1 1 in the 2 2 mode there is no input number 3 Break time 176 s MBF time 0 s MBB time 0 s IP address 192 168 0 50 Subnet mask 255 255 255 0 Gate...

Страница 18: ...reen is unreadable and only the characters are visible or the screen is completely white then after pressing the Esc button 10x the device will signal its presence in the LCD contrast menu by blinking...

Страница 19: ...annels number 512 ENTER ENTER Fixed value 127 ENTER Fixed value 127 NEXT Fixed value 0 ENTER Fixed value 127 DMX timings MBF time us 0 MBB time us 0 ENTER Break time us 176 Network config ENTER IP add...

Страница 20: ...PX788 works in the same subnet as the computer and that there is no conflict of IP addresses devices must have unique IP addresses in the network If the merger obtained the IP address from the DHCP s...

Страница 21: ...n the operating system Windows 7 system is an example here Change of the computer network configuration in the Windows 7 operating system in done in the following 1 Click Start 2 Select Control Panel...

Страница 22: ...6 Right click on Po czenie lokalne Local area connection and choose the Properties 7 In the new window that appears select Internet Protocol Version 4 TCP IPv4 and then press properties 22...

Страница 23: ...ect Use the following IP address To connect directly computer driver with a controller that has a default configuration use the sample settings IP address 192 168 0 51 Subnet mask 255 255 255 0 Defaul...

Страница 24: ...server running the network configuration on all devices in the network is set automatically The second option is to connect the merger and PC to a switch or router that does not support DHCP server i...

Страница 25: ...e DHCP server operates 25 PX788 Merger DMX 3 1 PX788 DMX Merger 172 168 1 152 A computer connected to the router via WiFi with automatically downloaded network settings from a DHCP server DHCP On PX78...

Страница 26: ...network is described in section 7 Remote connection 26 PX788 Merger DMX 3 1 PX788 DMX Merger 192 168 0 50 Przyk adowe ustawienia sieciowe PC po czonego z routerem za pomoc WiFi IP 192 168 0 51 Maska...

Страница 27: ...is always displayed on the home screen of the device NOTE Pay special attention if the PX788 is in the same network as the device on which the browser is running or in the router there are redirects...

Страница 28: ...ts DMX output 1 DMX output 2 setting the number of channels sent to the output the method of merging the input signals and the output DMX signal Administration change of the device name operating mode...

Страница 29: ...The following options are in the upper right corner device serial number language change EN DE PL restarting the device device and manufacturer information 29...

Страница 30: ...es depending on the mode 2 or 3 inputs number of DMX output channels and their values depending on the mode 1 or 2 outputs Depending on the mode a preview of 2 input lines and 2 DMX output lines or 3...

Страница 31: ...escribed in detail in section 4 3 2 Merge signals are HTP LTP Fixed Capture Mixed Priority 1 2 2 1 for mode 2 2 1 2 3 1 3 2 2 1 3 2 3 1 3 1 2 3 2 1 for mode 3 1 For each input the user specifies the r...

Страница 32: ...DMX channels sent per output merging signals graphical representation of signal merging range of DMX channels that will be merged range of DMX channels to which the integrated signal will be sent rea...

Страница 33: ...e name user set custom device name Serial number Operating mode 2 2 or 3 1 to choose from IPv4 setting the IP address Mask setting the subnet mask edited by changing the CIDR in the range 1 30 33 cust...

Страница 34: ...parameters Factory settings restore factory settings in the device 4 5 3 Restore default settings Update device software update the latest version for download is available on the manufacturer s websi...

Страница 35: ...block selected port in the router s firewall the address of the merger mergers in the local network can not change the merger must have a static IP address set or the DHCP server must assign the same...

Страница 36: ...MAC address 70 B3 D5 EF B1 60 the IP address 192 168 1 15 will always be assigned by the DHCP server example below Most routers available on the market usually have several parameters in port forwardi...

Страница 37: ...otocol TCP or TCP UDP in this case option Both Below is the screen of the example setting in the router If the router does not have the option to set up one port forwarding create a range from 80 to 8...

Страница 38: ...er ports 38 INTERNET PX788 Merger DMX 3 1 PX788 DMX Merger 192 168 1 50 A computer connected to the internet PX788 network settings IP 192 168 1 50 Masa 255 255 255 0 Gate 192 168 1 1 DHCP Off Externa...

Страница 39: ...arget device port 80 protocol TCP or TCP UDP in this case option Both Below is a screen with examples of settings in the router port forwarding 2000 and 2001 to the appropriate IP address of the merge...

Страница 40: ...5 255 0 Gate 192 168 1 1 DHCP Off A computer connected to the internet PX788 network settings IP 192 168 1 50 Masa 255 255 255 0 Gate 192 168 1 1 DHCP Off External IP address 66 77 88 99 2000 66 77 88...

Страница 41: ...device is working properly flashes contrast editing mode DMX input output blinks blue receiving DMX signal is off no DMX signals at the input blinks yellow DMX signal is sent at the output NOTE The DM...

Страница 42: ...d not to the next DMX receivers From DMX OUT pins outgoing DMX signal you should route the signal to DMX receivers DMX IN DMX OUT GND GND CORRECT DMX 512 input DMX 512 output DMX IN DMX OUT GND GND WR...

Страница 43: ...2 24V DC power consumption max 3W DMX channels 512 DMX IN OUT 2 2 or 3 1 programming 2 x 16 LCD display and 4 buttons Web Server output connectors screw terminals weight 0 15kg dimensions width 105mm...

Страница 44: ...ng directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Tex...

Отзывы: