PLATINUM
WATER HEATER
19
PV500-37C 06/12
WARNING: Setting the temperature selector to higher settings provides hotter water, which increases
the risk of scald injury. If this appliance is used to produce water that could scald if too hot, such as
domestic hot water use, reduce the water temperature setting and utilize a system or point-of-use
temperature limiting valve to obtain a water temperature of 120ºF or less. See the “IMPORTANT SAFETY
NOTE” concerning hot water temperatures located near the front of this manual.
WARNING: Should overheating occur or the gas supply fails to shut off, do not turn off or disconnect the
electrical supply to the appliance. Instead, shut off the gas supply by turning off the manual gas valve
external to the appliance. Turning off or disconnecting the electrical supply to the appliance during
these conditions could result in a fire, explosion or exposure to hazardous materials, causing property
damage, personal injury or loss of life.
9.7 Thermostat
Settings
The adjustable operating temperature control is located between the upper and lower front control panel covers.
This control utilizes a temperature sensing thermistor located in the control flange on top of the tank. Follow the
safety instructions and warnings included in this manual and with the product, when adjusting the set point of the
operating temperature control to deliver the desired water temperature.
The setpoint
(SET)
determines the desired stored water temperature in the tank and is factory set at
approximately 120°F. If the tank temperature decreases below the set point a call for heat sequence is activated.
The heating sequence is turned off when the tank temperature again reaches the set point value.
To View the Setpoint
1. Press and quickly release the
“SET”
key. This will display the setpoint for 5 seconds.
To Change the Set Point
1. Press and hold the
“SET”
key for at least 2 seconds to enter the setpoint change mode.
2. The setpoint is displayed and the LEDs of the first and third digits blink.
3. To change the value, use the
“UP”
and
“DOWN”
keys.
4. The new value can be stored either by pressing the
“SET”
key (the control restores temperature display)
or by waiting the exit time-out to expire (15 seconds).
Key
Combinations
1. TO UNLOCK THE KEYBOARD: Press and hold the
“UP”
+
“DOWN”
keys for 3 seconds. When the
“PON” flashing message is displayed, the keys are unlocked.
2. TO LOCK THE KEYBOARD: Press and hold the
“UP”
+
“DOWN”
keys for 3 seconds. When the “POF”
flashing message is displayed, the keys are locked.
3. TO RETURN TO TEMPERATURE DISPLAY: Press the
“SET”
+”
UP”
keys.
9.8
High Water Temperature Limit Control
All PLATINUM
water heaters are equipped with preset limit and high limit controls to provide control of the
maximum discharge water temperature. These controls are located inside the upper front control panel and are
not user adjustable.
WARNING:
High Voltage Shock Potential - Turn off all electrical service to the appliance when accessing
limit or high limit controls located inside the control panel. After access, close and fasten the panel
cover before restoring electrical service to the appliance. Wires and terminals carry High Voltage (120V).
If the electrical service is not turned off, or if the panel cover is not replaced, and these terminals are
touched, a dangerous shock causing personal injury or loss of life could occur.