Troubleshooting
Troubleshooting
Problem
Possible Cause
Corrective Action
Material does not
dispense
•
Material cured in nozzle plate
•
Nozzle is clogged
•
Material accumulation around
nozzle
•
Disassemble and clean nozzle
•
Clean outside of nozzle with wipe or
vacuum purge
Material leaks
from the nozzle
plate
•
Jet pressure is too low
•
Jet needle is worn or dirty
•
Nozzle is worn or dirty
•
Increase the jet pressure, the
maximum pressure is 90 psi
•
Clean or replace jet needle
•
Clean or replace nozzle plate
Material leaks
from between
fluid body and air
body
•
Fluid body O-ring is worn or dirty
•
Clean fluid body
•
Clean or replace O-ring
Material splatters
•
Jet pressure is too high
•
Decrease jet pressure
•
Increase distance to target
substrate
Dispense size is
inconsistent
•
Nozzle is clogged
•
Material thickens when static
•
Disassemble and clean nozzle
•
Run pre-dispense routine or
add purge sequence at start
of dispense