Jet and Fluid Pressure
6.1
The PVA JDX Jet Valve controller has integrated air regulators (7, 10) which control the
pressure to the Jet and the Fluid supply. Two digital gages (2, 6) show the pressure
levels. The Fluid Pressure can be turned off with the air switch (11).
The jet requires a minimum of 35psi to function correctly. In general, 45psi is a good
starting point for jet pressure. If the jet does not break off cleanly, increase the jet
pressure. If you increase the jet pressure to 65psi and still have accumulation, increase
the material temperature.
Temperature Controller
6.2
The main menu of the temperature controller shows the current temperature (PV) on
the top line, and the set point temperature (SV) on the bottom line of the display.
Figure 33: Temp Control
To change the SV temperature
6.2.1
1.
Use the UP/DOWN arrows to increase or decrease the temperature.
2.
Press the ENTER key to save the change.
Figure 34: To Change the SV Temperature
Set Point Temperature
Enter Key