BI2000 Board Inverter Manual
Revision F
/
February 2020
Page 11 of 37
Setup
WARNING: These procedures should be done by a qualified person in accordance with
this manual and applicable safety regulations. A “qualified person” is defined as “a
person or persons who, by possession of a recognized degree or certificate or
professional training, or who, by extensive knowledge, training, and experience, has
successfully demonstrated the ability to solve problems relating to the subject
matter and work.” (ref. ANSI/ASME B30.2-1983.)
Installation
1.
Plug the machine into an appropriate power source as shown by the Machine
Specific Information section of the Operating Guide or the legend plate on the
machine. The electrical service should be correctly grounded and the power source
“clean”. If there is high power equipment operating off the same source, a line
conditioner may be necessary. Machine errors can be caused by poor quality power.
WARNING: Failure to comply with electrical specifications can damage the machine
and injure personnel. Electrical hookup must be made by a qualified electrician and
comply with any local standards.
2.
Connect the ¼” NPT female fitting at the rear of the machine to a source of clean,
dry air. A hose of ¼” inside diameter is sufficient.
Figure 3: Main Air Attachment
3.
Close any access doors and engage the
“Emergency Stop”
button.
4.
Turn the red air lockout valve to “
SUP
”.
5.
Make sure any SMEMA cables are correctly connected.
6.
Turn the main power to switch “
ON
”.