Troubleshooting
Problem
Possible Cause
Corrective Action
Pressure will not build
•
Doors are not closed
•
3-position hand lever is in
the RAM HOLD position
•
Ram Up pressure or Ram
Down pressure is too low
•
Main air supply is shut off
•
Shut door correctly
•
Put the 3-position hand lever in
RAM DOWN position
•
Use the Ram Regulator to increase
pressure to the pump
•
Open main air supply valve
Material leaks past the
ram seal
•
Seal is torn or damaged
from seam inside pail
•
Seal is twisted or not
correctly seated in the ram
groove
•
Pail is deformed or
otherwise damaged
•
Inspect the welded seam inside
pail for sharp edges, replace ram
seal if necessary
•
Refer to Section 6.2 for correct
ram seal installation instruction
•
Return pail to material
manufacturer and replace with
pail that is not damaged
Hydraulic pump cycles
rapidly when system is
up to pressure
•
Contamination in the
hydraulic pump spool valve
•
Worn seals in the hydraulic
pump spool valve
•
Reference attached manual for
Haskel 4B series air driven
hydraulic pump
•
Reference attached manual for
Haskel 4B series air driven
hydraulic pump
Inconsistent dispense
volumes through the
applicator valve
•
System not correctly bled
of air
•
Supply hose to dispense
valve is sized too small
•
Hydraulic pump is not
holding consistent
pressure
•
Refer to Section 5.3 for
instructions on how to bleed the
pump
•
Consult PVA for correct hose
sizing
•
Reference attached manual for
Haskel 4B series air driven
hydraulic pump