7
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net
ONECONNECT DIAGNOSTIC GUIDE
TROUBLESHOOTING:
DUAL POLE WITH INTERIOR LIGHTS
INTERIOR LIGHTS DO NOT COME ON
Step1: Inspect the wiring and confirm that all connections are tight.
Step 2: Turn the interior lights on by pressing the switch on the nosebox, then
continue to the following steps.
Step 3: Check for a voltage greater
than 10 volts to the lights, as
shown.
• If yes, inspect the wiring
between the nosebox and the
lights for defects.
• If no, continue to the next step.