22
Troubleshooting
Purivox Triplex V doesn´t bang:
1.
Check the gas bottle capacity; remove the gas hose from the solenoid valve
an dip the hose into a bucket of water and open the gas valve.
Smoke or open fire in this situation can be dangerous!
2.
If the gas bubbles in the water, check the hose for leaks.
3.
Check the hose connections on the solenoid valves. Is the direction of the gas
flow the same as the arrow on the solenoid valve? Don´t kink the hoses.
4.
Is the propane jet from the jet hose screwed into the injector?
5.
Battery check: Each battery must have a minimum voltage of 5 volts. Is the
transmitter in function? If necessary check the voltage of batteries with a
voltmeter in the workshop of your dealer. If the combined voltage has
dropped to 9,0 volts, or the short circuit current of the single batteries drops
under 1 ampere, replace the batteries.
6.
Is the time at the timer set correctly? Maybe control.
7.
Is the outside switch at position “1” ON?
8.
Spark control. Is the spark cable intact? If the cable is damaged, please
don´t fix it by yourself! Warning: High voltage spark! Distance between
the electrodes of the ignition spark should be approx 5mm. Test the
controller function without gas flow turned on!
Hold ignition spark plug
holder together with the earth cable to the metal bracket. Don´t touch
the spark gap with your fingers while switching the unit ON. Don´t run
the earth cable and spark cable next to each other.
9.
The unit has a self reset security safety element. Please watch out for
potential short circuits between the connecters.
10. Timer is set wrong.
11. The timer has no internal battery. So after removing the batteries or
when the batteries are totally flat, the time must be reset when
Notes: If the device is not in use you have to - in order to avoid
damage to the electronic units by leaking batteries - remove the
batteries mandatory. Close the unit and store it dry.
Purivox Triplex V bangs at times, when it shouldn’t bang.
PURIVOX Saat- und Ernteschutzgeräte GmbH
Hauptstrasse 11
D - 67308 Ottersheim
Ph: 0049-6355/9543-0
Fax: 0049-6355/954329
Internet:
www.purivox.com
Email: