User Manual
PT-PMS-42
30
8.2 RS232 Communication Command
Communication protocol:
RS232 Communication Protocol
Baud rate: 9600
Data bit: 8
Stop bit: 1
Parity bit: none
8.2.1 Device Control
Command
Description
Feedback Example
PowerON.
Power on system.
Power ON!
PowerOFF.
System standby.
Power OFF!
/*Name.
Report system name.
4x2 Matrix Switcher
/*Type.
Report system model.
PT-PMS-42
/^Version.
Report firmware version.
V1.0.0
STA.
Report system status.
… …
Lock.
Lock front panel buttons.
Front Panel Locked!
Unlock.
Unlock front panel buttons.
Front Panel UnLock!
GetGuiIP.
Report GUI IP.
GUI_IP:192.168.0.178
SetGuiIP:
[xxx.xxx.xxx.xxx].
Set GUI IP to [xxx.xxx.xxx.xxx].
SetNoSigTime:[xxx].
Set the automatic power-off time to xxx. Set
the “xxx” as “0” to disable this function.
No Signal Auto StandBy Time Is
0S!
Rs232HDBTBypassON.
Enable RS232 pass-through mode.
Note: This function can only be disabled by
Telnet or GUI.
Rs232 HDBT Bypass ON!
Rs232HDBTBypassOFF.
Disable RS232 pass-through mode.
Note: The command must be send by
Telnet port or GUI RS232 tab.
Rs232 HDBT Bypass OFF!
RemoteCtrMcuON.
Allows the switcher to be controlled by the
far-end control device which is connected to
the RS232 port of HDBaseT receiver.
Remote Control MCU ON!
RemoteCtrMcuOFF.
The switcher cannot be controlled by the
far-end control device
Remote Control MCU OFF!
RST.
Factory reset.
Factory Default!