User Manual
PT-C-HDCEC
16
Command
Function
Feedback Example
RS232U/-[X]:XXX
Set the user-defined HEX command to
send to the third-party device (e.g.
projector) whose baud rate is X.
RS232USER/-3:30 31 32
Send the user-defined command
“30 31 32” to the third-party
whose baud rate is 9600.
RS232DLY:[XXX].
Set the sending interval time between
RS232 ON and RS232 USER to XXX
(default 3s, range of 1S to 180s).
SET RS232 ON DELAY TIME [XXX]S
RS232PCS[X].
Set the sending number of RS232 OFF to
X.
X
Description
0
1 time
1
2 times
SET SEND RS232 OFF ONE TIME!
RS232OFFDLY:[XX].
Set the two times sending interval time
of RS232 OFF to XX (default 2s, range of
1S to 10s).
SET RS232 OFF SEND DELAY TIME
[XXX]S
GRS232DLY.
Report the sending interval time
between RS232 ON and RS232 USER.
SET RS232 ON DELAY TIME 3S
GRS232PCS.
Report the sending number of RS232
OFF
SELECT SEND RS232 OFF ONE
TIME!
GRS232OFFINT.
Report the two times sending interval
time of RS232 OFF.
SET RS232 OFF SEND DELAY TIME
2S
6.1.5
IR Control Setting
Command
Function
Feedback Example
IRSTUDY[X].
Learns the IR command from IR remote.
X
Description
0
STUDY IR DISPLAY OFF
1
STUDY IR DISPLAY ON
2
STUDY IR USER
IRSTUDY0.
READY STUDY IR DISPLAY
OFF,PLEASE REMOTE CONTROL
RECEIVER IN 10S!