Reverse Osmosis User Guide

1.5" Air Gap Required

Inlet-1/2" Natural

Drain - 3/8" Black

Feed Water Valve

Cold Water Line Only

Feed Pressure 

Gauge

RO Assembly

External Prefilter

Product Storage Tank

To Point of Use

Vented to

Atmosphere

Liquid level float 

sensor to control

feed solenoid valve 

Feed Solenoid

Valve

Figure 4  Typical Light Commercial Installation

THE BASIC REVERSE OSMOSIS SYSTEM cont.

Typical Light Commercial Installation

Installation Guide

Fig. 3

Содержание ROS2700

Страница 1: ...User Guide Reverse Osmosis Water Treatment System ROS2700 For correct operation installation it is essential to observe these instructions SEPT2020...

Страница 2: ...laboratory every six months The laboratory should be certified for testing the specific contaminants of concern For a listing of certified laboratories contact local regulatory agencies Consult your l...

Страница 3: ...limits A water quality analysis can be performed to determine if incoming water requires any treatment Contact your dealer installer The filters and membrane elements in the RO system need to be repl...

Страница 4: ...AR INSTALL KIT LOCKING BAR DISCONNECT 3 8 INCH COLLET LOCK CLIP 1 2 INCH COLLET LOCK CLIP SOME CONFIGURATIONS MAY NOT INCLUDE ALL COMPONENTS LISTED BELOW TUBING INSTALL KIT 3 8 BLACK TUBING 4 ft 3 8 B...

Страница 5: ...RO membrane element Drain Point A suitable drain point is needed for reject water from the RO system A floor drain laundry tub standpipe sump etc are all acceptable If discharging into the utility sin...

Страница 6: ...r Gap 1 5 Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont...

Страница 7: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Страница 8: ...t Be sure it will fit flat against the sink or counter and that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole Warning To avoid damaging a sink consult a...

Страница 9: ...nst the clip to hold the faucet in position Installation Guide ater supply and open a low faucet to d style The installer will determine nstall a valve on the cold water tubing If threaded fittings ar...

Страница 10: ...s intended for use only durin installation and troubleshooting of the RO system The pressure gauge should be removed during normal system operation because some regulatory agencies did not evaluate th...

Страница 11: ...e Ensure that the support leg is installed on the sumps Installation Guide NOTE Make sure the tubing is pushed past the O rings for a secure fit Also when replacing any tubing cut tubing back 1 4 inch...

Страница 12: ...d Connector Symbol Connection Tubing Colour Feed Inlet Natural Concentrate Black Product Blue Warning Be sure to lubricate the manifold ports with silicone lubricant prior to inserting the fittings in...

Страница 13: ...side 4 Purge the system Open the faucet and run the water through the RO system for two to eight hours Note A minimum of 2 hour flush is required to remove the food grade preservative After 8 hours pe...

Страница 14: ...ystem into a contained area such as a sink or tub 5 Remove the support leg from the three sumps and unscrew the top sump as shown to access the prefilter element The support leg functions as a wrench...

Страница 15: ...ain a food grade preservative The use of sterile latex gloves is highly recommended c Lubricate element O rings brine seals and sump O rings with silicone lubricant Refer to Connection Lubrication on...

Страница 16: ...w direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manifold and lock in position with locking bar 12 Re position the assembly and turn the wat...

Страница 17: ...Inlet Turbidity 0 1 NTU Dimensions Performance Specifications Minimum and Maximum Operating Conditions Condition Minimum Maximum Inlet Pressure 40 psi 2 76 bar 80 psi 5 52 bar Inlet Temperature 40 F 4...

Страница 18: ...lugged post filter If flow into the post filter is acceptable replace post filter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugge...

Страница 19: ...19 Copyright Puretec Pty Ltd 2020 Reverse Osmosis User Guide Installation Information 14...

Страница 20: ...ed or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 4464398 PO Box 875 Cam...