25
Puretec Radfire RI Series
Copyright © Puretec Pty Ltd 2021
Performance Data Sheet
NSF / ANSI Standard 55, Class A Systems (RI-17KA)
System Tested and Certified by
NSF International against CSA B483.1 and NSF/ANSI 55
for Disinfection Performance, Class A
Model
RI-17KA
NSF Class A Flow Rate
(40mJ/cm2 @ 70% UVT)
18 gpm
68.1 lpm
4.08 m
3
/hr
Port Size:
1½” MNPT
Electrical:
90-265V/50-60Hz. 1.5A Max
Operating Pressure:
0.7-10.3 bar (10-150 psi)
Operating Water Pressure:
2-40° C (36-104° F)
Lamp Life:
UV lamps are rated for 10,000 hours of continuous use (approximately 14 months
of operation).
General Operation and Maintenance:
UV lamps are to be replaced on an annual basis. Quartz
sleeves and UV sensors are to be cleaned every 6 - 12 months and replaced every 5 years.
This Class A system conforms to NSF/ANSI 55 for the disinfection of microbiologically
contaminated water that meets all other public health standards. The system is not intended to
convert wastewater or raw sewage to drinking water. The system is intended to be installed on
visually clear water.
NSF/ANSI 55 defines wastewater to include human and/or animal body waste, toilet paper, and
any other material intended to be deposited in a receptacle designed to receive urine and/or
feces (blackwaste), and other waste materials deposited in plumbing fixtures (greywaste).
If this system is used for the treatment of untreated surface waters or ground water under the
direct influence of surface water, a device found to be in conformance for cyst reduction under
the appropriate NSF/ANSI standard shall be installed upstream of the system.
While testing was performed under standard laboratory conditions, actual performance may vary.
The systems and installation shall comply with applicable provincial/state and local regulations.
RI-17KA Performance Data
Содержание Radfire RI Series
Страница 28: ......