Puretec Radfire RAS Series Скачать руководство пользователя страница 4

4

 

Installation & Operation Manual

Copyright © Puretec Pty Ltd 2020

Operation

Operation 

The Radfire™ Portable Air Santiser comes ready to use. Simply unpack the unit, plug it in and 

turn it on. 

Once the system is turned in, the Radfire™ lamp will ignite and emit a blue glow from each 

end of the cabinet. 

Note:

 The glow is perfectly safe as the rays are completely contained within the cabinet.

The fan will also start operating, drawing air from one end of the unit, pushing the treated air 
out of the other end. 

Treated Area Coverage 

One unit is recommended to treat a room/area with a cubic area of approx. 40 cubic meters. 

For example: 

A room that measures 4.5 m (W) x 4.5 m (D) x 2.5 m (H). 

In a room of this capacity, the Radfire™ Portable Air Santiser will achieve 4 complete cycles 

of the room volume every hour (60 minutes). Larger rooms/areas will require multiple units 
based on this ratio.

Calculation of cubic meters: 

• 

length (m) x width (m) x height (m) = cubic meters (m

3

); or

• 

length (cm) x width (cm) x height (cm) / 1,000,000 = cubic meters (m

3

); or

• 

length (mm) x width (mm) x height (mm) / 1,000,000,000 = cubic meters (m

3

).

Specifications 

Coverage: Up to 40 m3

Fan Size: 120 mm computer type 

Fan Capacity: 160 m

3 per hour 

Fan Noise Level: Up to 

55 dba

Lamp Type: UVC 

20W, 254 mm 

Power: 240V, 50HZ

Содержание Radfire RAS Series

Страница 1: ...For correct operation installation it is essential to observe these instructions APR2020 User Guide Radfire Portable Air Sanitiser System RAS Series...

Страница 2: ...er manufactured from quality materials and components and will give years of fresh air free of impurities if maintained and used properly For advice or further questions please contact your local Pure...

Страница 3: ...ents The system can be used in any areas where cross infections occur due to human congregations during social functions and business practices Ideal use for Hospitals Intensive Care Burns Unit Emerge...

Страница 4: ...One unit is recommended to treat a room area with a cubic area of approx 40 cubic meters For example A room that measures 4 5 m W x 4 5 m D x 2 5 m H In a room of this capacity the Radfire Portable A...

Страница 5: ...l not to pull on the connecting wires 3 Unclip the lamp from the holders by gripping the ends of the lamp and gently but firmly pull the lamp free from the clips 4 Hold the end of the lamp that is con...

Страница 6: ...t expenses of claiming under this warranty You may submit details and proof of your expense claim to place of purchase for consideration The warranty only applies if the product was used and or instal...

Страница 7: ...ed to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Re...

Страница 8: ......

Отзывы: