12
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2018
3. Connect the ballvalve to the multivalve with a piece of white tubing (see fig 1).
4. Install filter cartridge by positioning it in the desired location, marking the position of
fixing hole and fixing with bracket screw. (QT12 Series can be mounted horizontally
or vertically) Allow room for the connecting tubes. Ensure flow arrow on cartridge is in
direction of water flow.
5. Fit tubing into connectors (for quick-connect fittings see fig 2). Allow slack in the
tubing. Connect the tubing into the filtered water flexible hose (plain).
6. Connect cold water flexible hose (blue streak) to cold mains water supply and the hot
water flexible hose (red streak) to the hot water supply.
7. Restore water supply & check for leaks, rectifying them, if any, before leaving the unit.
8. Run the system for at least 5 minutes to remove carbon fines. Water may appear
milky, but this is normal and is only tiny air bubbles that will clear after a short period.
Cartridge Installation/Changeout
1. Place container under filter in case of drips.
2. Twist out old cartridge. Discard old cartridge.
3. Remove packaging from the new cartridge including the yellow cap on top of the
cartridge. Twist in the new cartridge. Ensure firm seal to head.
Replacement cartridge code:
Puretec
QT12R
4. Reset LED indicator by following instructions on page 6.
5. Restore water supply.