background image

PRO SERIES     Drinking Water Systems

USER GUIDE

PRO SERIES     Drinking Water Systems

Copyright © Fluid Products Pty Ltd 2012

4

INSTALLATION PROCEDURE - 

See Figure 1

1.

  The unit comes with a Tap Adapter on the inlet side, identified by GREEN hose, which will 

screw onto a standard tap without the need of thread seal tape. Make sure it is firmly screwed 
to provide a seal on the rubber gasket (hand tighten only).

2.

  To gain access to the mounting screw holes on the mounting bracket, simply unclip the 

R.O. housing from the clip attached to the main mounting bracket. This will reveal the wall 
mounting screw holes to enable the mounting of the system to the wall, cupboard etc.

3.

  Purified water (BLUE hose), and waster water (BLACK hose) lines do not come with any 

attachments. Pure water should be directed to a suitable container without any back pressure 
or valving occurring in the line. The drain line, or waste water may be directed to the outside 
garden, or if installed inside, to a washing machine, to conserve water. If inconvenient it may 
be directed to any drainage system.

4.

  When the unit is in place and the water lines are installed, the unit should be run for four (4) 

hours before the purified water is used, on initial start up. The unit cannot be stored for more 
than two weeks without use, or damaged to the membrane may occur. Please enquire if this is 
the case. 

  For a period of non-use greater than 2 days, flush for 10 min before use. For non-use greater 

than 2 weeks, the cartridges may need replacing.

5.

   The Sediment and Chemical Removal Filters should be replaced every six (6) months. The 

membrane should be replaced when water quality deteriorates or every 18-24 months, 
depending on incomming water quality. 

A Puretec TDS meter (PTE10) can determine quality 

for you at the push of a button. 

  For best performance use only genuine Puretec replacement cartridges and cartridges that are 

suitable for this appliance.

Содержание PRO Series

Страница 1: ...PRO SERIES Drinking Water Systems USER GUIDE For correct operation installation it is essential to observe these instructions Installation operation manual for Drinking Water Systems PRO Series ...

Страница 2: ...instructions For cartridge replacements contact your nearest Puretec stockist Puretec Customer Service Helpline 1300 190 190 OPERATION Puretec systems are designed to run economically for many years and this is dependant on the initial installation and periodical maintenance Flush systems for 10 minutes after any period of non use more than 2 days For a period of non use of 2 weeks or more it may ...

Страница 3: ...ing cap can be unscrewed by hand 3 Cleanse the inside of the housing using Puretec S500 Sanitiser Check O Ring and lubricate with food grade silicone lubricant or similar Replace O Ring if kinked or damaged 4 Install new cartridges and replace housing screwing them up HAND TIGHT ONLY PX051 filter is on the inlet side and CB951 on the outlet side 5 Restore water supply check for leaks rectifying th...

Страница 4: ...ccurring in the line The drain line or waste water may be directed to the outside garden or if installed inside to a washing machine to conserve water If inconvenient it may be directed to any drainage system 4 When the unit is in place and the water lines are installed the unit should be run for four 4 hours before the purified water is used on initial start up The unit cannot be stored for more ...

Страница 5: ...e tubing 5 Pure Water Outlet Blue flexible tubing 6 Membrane Housing 7 Mounting Bracket 8 Chemical Filter Housing 9 Sediment Filter Housing 1 2A 5 4 4 5 9 8 2 2A 6 7 SEDIMENT REMOVAL CHEMICAL REMOVAL END VIEW OF MEMBRANE HOUSING 2 3 User Guide Copyright Fluid Products Pty Ltd 2012 PRO SERIES Drinking Water Systems USER GUIDE 5 ...

Страница 6: ... 2 1 Cut the tube square and push in to the tube stop For metal tube remove burrs and chamfer tube end to prevent O Ring seal being damaged DISCONNECTION PROCEDURE 4 Push collet against body and slide tube out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position PERFORMANCE DATA PRO SERIES Drinking Water Sy...

Страница 7: ...e in taste odour or decrease in flow 8 000 litres is approximately equal to using 20 litres daily for one year Caution Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system SUBSTANCE REDUCTION The Water Filter models listed above have been tested and certified under AS NZS 3497 and AS NZS 4348 for reduction of chlorine...

Страница 8: ... claiming under this warranty You may submit details and proof of your expense claim to place of purchase for consideration This warranty is given by Puretec ABN 66 474 243 571 14 16 Bailey Street St Marys SA 5064 telephone no 1300 190 190 and email at sales puretec com au This warranty is provided in addition to other rights and remedies you have under law Our goods come with guarantees which can...

Отзывы: