3
Puretec Basic SIB / TW Series | Drinking Water Filter Systems
5.
Install new cartridges and replace housing screwing them up HAND TIGHT ONLY. Sediment
filter is on the inlet side and chemical on the outlet side.
6.
Restore water supply & check for leaks, rectifying them, if any, before leaving the unit.
After installing cartridges flush unit for 5 - 10 minutes.
Installation
This system comes complete with an installation kit enabling it to be connected to 15mm (½”)
copper pipe (Cold supply only - hot water should be filtered prior to heating). Included is a
control valve incorporating backflow prevention, anti hammer, flow control and pressure limiting
capabilities according to The Australian Standards in full compliance with the relevant laws.
Note:
the PLV is standard in selected systems.
Installation Note
: A water filter system/tap, like any product, has a limited life and may
eventually fail. Also sometimes failure happens early due to unforeseen circumstances. To
avoid possible property damage, this product should be regularly examined for leakage and/
or deterioration and replaced when necessary. A drain pan, plumbed to an appropriate drain or
outfitted with a leak detector, should be used in those applications where any leakage could
cause property damage, and/or the water supply should be turned off if no one is home/present.
Installation Requirements
1.
15mm (½”) Cold water line.
2.
Supply pressure: 300 - 520 kPa (when pressure exceeds 520 kPa a pressure limiting valve
must be fitted).
3.
Supply temperature: 0° - 30°C (protect from freezing).
4.
Suitable location for faucet.
Alternative fittings may be required if being connected to anything other than 15mm (½”)
copper pipe. No electrical or drainage requirements needed.
Installation Procedure
1.
Select suitable location that is close to the point of filtered water delivery (eg. sink).
Remember to allow access room for changing filters and a suitable place where water
spillage will not cause damage. Location should not be in direct sunlight.
2.
Isolate water supply and cut copper pipe ready to install the ball valve.
3.
Connect the ball valve to the multivalve (if included, PL models) with a piece of white tubing
(see figures 1 & 3).
Flush with a small amount of water to remove any debris.
Installation