Operation regulation

The parts of UV-401

IN

OUT

UV water sterilizer

A.With everything connected, turn on the water check for leaks.

B.Let the water run for at least 30 minutes. This flushes the carbon

filters on first time use.

C.Change filters regularly every 6 to 12 months and have the

membrane checked annually.

Caution

1.Do not use hot water (over 45 C)!

2.Do not freeze the machine!

3.Switch off electricity and water source if away for more than 5 days,

and drain out pure water.

0

The 1st stage housing

The 2nd stage housing

The 3rd stage housing

IN

UV401 4 Stage Ultraviolet (UV) Water Purification System

UV401 4 Stage Ultraviolet (UV) Water Purification System

Содержание UV-401

Страница 1: ...UV works elections UV 401 Tubing connection diagram Installation diagram 08 Change filters Operation regulation FAQ Maintenance checking list Memo Thank you very much for selecting Pure Pro Water Cor...

Страница 2: ...and is extremely effective in killing many species of bacteria mold spores viruses and other microorganisms No longer fear drinking water from your own faucet Maintenance checking list UV401 4 Stage U...

Страница 3: ...ballast must be able to accommodate applications with this requirement Some of the other features users might expect from the electronic ballast are small physical size long life and high efficiency A...

Страница 4: ...requent cleaning No longer will you find the white scum on the inside of pans after boiling water Q How much water does the Pure Pro system produce Q Don t people need minerals removed from the water...

Страница 5: ...ro rated guarantee There are four major variables to consider 1 The greater the water pressure the better water quantity and quality it produced Water pressure of 60 PSI is ideal 2 76 F is the ideal w...

Страница 6: ...r check for leaks B Let the water run for at least 30 minutes This flushes the carbon filters on first time use C Change filters regularly every 6 to 12 months and have the membrane checked annually C...

Страница 7: ...tubing to the sink top faucet A B PRO PURE DRINKING WATER SYSTEM Operation regulation 3 Let the water run for at least 30 minutes This flushes the carbon filters on first time use 2 Plug in electrici...

Страница 8: ...ke out the UV sterilizer from the box as shown in the picture 2 Connect the wire to both ends of UV lamp 3 Tight up the UV cap Install UV lamp UV401 4 Stage Ultraviolet UV Water Purification System UV...

Отзывы: