PurePro HRO-400 Скачать руководство пользователя страница 8

1.Loosen the fitting nuts and the cap from the RO membrane housing as shown in 

the picture. Unpack the RO membrane and insert to its housing (rubber gasket 
towards to the open end). When completed, tighten up the cap with the RO 
membrane housing and the jaco fittings.

2.Turn off the water supply. Loosen the stainless steel pipe connector.

PR

O

P

U

R

E

D

R

IN

K

IN

G

   W

A

TE

R

   S

YS

TE

M

3.Get feed water connector and connect it to the stainless steel pipe as in the 

picture 2.

Jaco nuts 

Cold

Installation diagram

 P

U

R

E

-P

R

O

  

  

  

  

 R

E

V

E

R

S

E

  

O

S

M

O

S

IS

  

S

Y

S

T

E

M

07

PRO

P

URE

DRINKING   WATER   S YS TEM

PRO

P

URE

DRINKING   WATER   S YS TEM

3  

Unplug electricity.

4

  Open the housings clockwise.

7

  After changing filters, let water run 

    for about 15 minutes to clear the 
    filters.
    

Change filters

1  

Have a half-circle 

    housing wrench 
    ready.

12

 P

U

R

E

-P

R

O

  

  

  

  

 R

E

V

E

R

S

E

  

O

S

M

O

S

IS

  

S

Y

S

T

E

M

To RO system

2

  Turn off water source.

Be sure tighten with 
O-ring to prevent
from leaking.

5

  Insert new filter. 

   

To faucet

6

  Loose the fitting nuts at point 1,2. 

    Take out the jaco fittings, and seal 
    it up with the Teflon tape again. 
    Replace the new pre-filters.

1

2

HRO-400 High Capacity Reverse Osmosis System

HRO-400 High Capacity Reverse Osmosis System

Содержание HRO-400

Страница 1: ...y before installation and follow the regulations Type ofproduct Date of purchase Name Tel Address Memo USER S MANUAL HRO 400 HRO 400 High Capacity Reverse Osmosis System HRO 400 01 Introduction ofHRO 400 02 What isReverse Osmosis 03 Components Selections 04 Cartridge filters 05 The parts of HRO 400 06 Tubingconnection diagram 07 Installation diagram 12 Change filters 13 Change ROmembrane 14 Operat...

Страница 2: ...YSTEM PRO PURE DRINKING WATER SYSTEM PRO PURE DRINKING WATER SYSTEM Maintenance checking list Production 400 GPD 1512 LPD Operation Pressure 10 80psi Available in 110 volt 220volt 240volt 50 60 Hz Weight System 18 kg Dimensions 38 0 L x 25 5 W x 46 0 H cm Date Filters 1st stage 2nd stage 3rd stage 4th stage 6th stage Other items 5th stage Specifications Features 200 gallons perday membrane High fl...

Страница 3: ...icroorganisms from tapwater and produce sterile water Reverse osmosis is the reversal of the natural flow of osmosis In a water purification system the goal is not to dilute the salt solution but to separate the pure water from the salt and other contaminants When the natural osmotic flow isreversed water fromthe salt solutionis forced topass through the membrane in the opposite direction by appli...

Страница 4: ...half of that at 76 F The maximum 0 water temperature recommended is 85 F 3 Total Dissolved Solids TDS The higher the amount of dissolved contaminants in the water the lower the quantity of water produced A high level of TOTAL DISSOLVED SOLIDS can be overcome with additional water pressure 4 Membrane Different membranes have different characteristics Some produce more water than others some have be...

Страница 5: ...Carbon Filter 200 Gallon Per Day Membranes are now available in residential sizes Designed to perform in operating conditions similar to most standard under the counter home RO units the TW30 1812 200 forms a tight fit in most standard residential housings A With everything connected turn on thewater check forleaks B Within a few minutes up to 15 the water will start to run from the faucet slowly ...

Страница 6: ... 1 Plug in electricity 1st stage filterhousing 2nd stage filterhousing RO membrane housing Post carbon filter Input water To the faucet RO system main housing bracket 2 Turn on watersource ToRO system RO membrane housing The parts of HRO 400 Transformer Booster pump Electronic solenoid valve 3 Pumps start tofunction Booster pump HRO 400 High Capacity Reverse Osmosis System HRO 400 High Capacity Re...

Страница 7: ...TER SYSTEM Change membrane 3 Loose the Jaco fitting anti clockwise 4 Open the ROmembrane housing anti clockwise 5 Take out the old RO membrane with a handy tool 6 Insert a newRO membrane 1 Unplug electricity Tubing connection diagram 1 2 3 In Drain out Tofaucet 2 Turn offwater source HRO 400 High Capacity Reverse Osmosis System HRO 400 High Capacity Reverse Osmosis System 2 1 3 Faucet Input water ...

Страница 8: ...allation diagram PURE PRO REVERSE OSMOSIS SYSTEM 07 PRO PURE DRINKING WATER SYSTEM PRO PURE DRINKING WATER SYSTEM 3 Unplug electricity 4 Open the housingsclockwise 7 After changing filters let water run for about 15 minutes toclear the filters Change filters 1 Have a half circle housing wrench ready 12 PURE PRO REVERSE OSMOSIS SYSTEM ToRO system 2 Turn offwater source Be sure tightenwith O ring to...

Страница 9: ... onpage 06 Installation diagram 9 Take tubing white Wear the concave type screw on tubing white and insert the tubing shroud as shown in the picture Connect the tubing top with the faucet end Then connect the tubingend to thelast stage filter as point 3on page 06 10 Make sure that you complete No 1 to No 9 If so switch on water supply and plug in electricity PS Do notuse drink waterfrom the firstm...

Страница 10: ...nstallation diagram 8 Takeout the faucetand its components Install the faucetand the rubbergasket to the kitchenwaretable Install therest of componentas shown inthe picture Installation diagram Faucet Kitchenware table Twisted plasticlocker Rubber gasket Flat metal piece Screw locker PS To suit your kitchenware table you can choose to have twisted plastic locker or screw lockerto be installedfor y...

Отзывы: