![Purelogic PLDS880 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/purelogic/plds880/plds880_operational-manual_1627635003.webp)
Edition of 09.11.2016
3
PLDS880. Servo-step motor DSP driver
Specifications
Scope of Delivery
• PLDS880 step motor DSP driver - 1 piece
• Operational Manual - 1 piece
03
02
SSM step division (micro step)
Integral generator SSM speed
ERROR output parameters
Module net weight
STEP signal max. frequency
Module power supply voltage
SSM operating current
SSM max. speed
SB encoder support
Insulation resistance
Operating temperature
Diff.inlet, 500-1024 pulse/rev
500
MOhm
0...50 °С
1...512
0…500 rev/min
50V/50mA MAX
0.45 kg
200 kHz
18…80V (typical value 70V)
2А…10А
3000 rev/min
• All driver connections and operation mode changes shall be made
only with disabled power supply source
• Do not install power supply disconnector (circuit breaker) after
power supply source (at driver power supply line). Disconnector may be
installed only at ~220V side power supply unit inlet.
• Do not connect driver power supply in series. Only “star” type
connection is allowed (each driver separate power supply line is
connected to PSU).