background image

Edition from 05.06.2015 

9

PLCM-E1b. 

CNC Ethernet controller

www.purelogic.ru

8 (800) 555 63 74

05. Software installation 

3. Having installed the plug-ins, when starting MACH3 choose the 

appropriate plug-in in the window which is shown in fig. 7.

As a rule there are two versions of plug-ins for PLCM controllers: test 

and stable.

Choose the one you are going to work with. Tick ‘Don`t ask me

again ‘ in order not to choose it every time. If there is necessity to 

change output device choose: MACH3 – Function Cfg’s – Reset device 

sel.

* If you decided to go to another version (test or stable version, you will 

need to go to plug-in setting up after start-up (see further) and update 

internal controller software.

4. After successful plug-in start, PLCM control option will appear in 

menu MACH3 PlugIn. Choose this option.

* If you see the window as it is in fig. 8 and you cannot choose 

controlling device, this means that Windows firewall blocks access to 

PLCM-E1b. You must either add MACH3 to firewall exception or disable 

firewall. 

5. Execute plug-in setting.

Out of a falling out list it is necessary to choose one of the controllers 

connected to the system.

After choosing the option additional controller settings will be available 

(fig. 8). Пif the plug-in finds that weaving is out of date, you will be 

prompted to update weaving in the controller. This procedure needs to 

be performed once when first device installation. 

Settings description:

Advance path planning time of Mach3 – specifies data size about motion 

path, which the program needs to prepare beforehand. The more the 

value, the more stable the machine works (e.g. when ToolPath picture 

rotates , Mach stops calculating new trajectory data, therefore the 

more of them were calculated beforehand, there is the less possibility 

of ‘failure’ in motion while rotating the picture or some other load on 

Mach3).

Time of advance calculation of path of PLMach – similar buffer, 

not from Mach3 side, but in PLCM card. The buffer stabilizes the 

work under short lineouts PLCM<>Mach3 and under slowing down 

calculation of Mach.

Note: From one side the more value of these features, the better (the 

buffer is bigger, the work is more stable) but with increase of buffer 

FeedHold will be delayed by the sum of these parameters, i.e. If 

Mach3 buffer=1 sec and PLMach buffer=0,5 sec, CNC-system reaction 

time when pressing FeedHold =1,5 sec + stepper motor braking time 

according to the defined acceleration profile.

Logging – with active logging, log exchange file PLCM<>Mach3 is 

saved to ‘C:\Mach3\PLСM.log’. When exploring incorrect device work, 

this file must be sent to Purelogic R&D technical Support with the 

detailed problem description. To receive IP-address automatically we 

recommend to leave this item active, if there is a device which can 

dynamically assign IP-addresses (e.g. it can be a usual home network 

gateway for internet connection )in you local network.

Usage of the following IP-address – this option must be used when 

there is no DHCP-server which appoints IP-addresses.

Fig. 8.

 Plug-in setting in MACH3

Содержание PLCM-E1b

Страница 1: ... General information 02 Delivery set 03 Technical features 04 Main connectors and indicators 05 Software installation 06 Terms of Warranty INSTRUCTION MANUAL 2 2 3 3 4 16 PLCM E1b CNC Ethernet controller ...

Страница 2: ...83 х 27 х 66 mm 250mА 100 kHz 12 items buffered 5V 10mA MAX 500 mOhm 0 3 kg 5 items buffered logic levels 0 1 8V 1 2 5V Max input voltage is 15V Ethernet connector RJ 45 signal transmission STEP DIR ENABLE and input signals MACH3 compatible Check www purelogic ru for more information POWER OFF DEVICE BEFORE MAKING ANY CONNECTIONS DO NOT CONNECT POWER SUPPLY S TO GROUND MASS HOUSING ETC IT IS RECOM...

Страница 3: ...htly differ in different network cards 2 For device work with MACH3 you need to install plug in Please download zip file for PLCM controllers from here www purelogic ru files downloads SOFT PLCM zip and run setup exe Software installation wizard for controller will be started fig 4 Press Next If this is your first installation and you want to have all necessary drivers installed choose devices whi...

Страница 4: ... in option When choosing PLCM E1b after Next pressing software installation wizard will offer to execute automatic setting of network adapter PC for correct connection to PLCM E1b fig 6 Controller automatic search can disrupt local network use this function only if you do not use local network resources on the PC and do not use the Internet Press Next then Install The master will copy the necessar...

Страница 5: ...gs description Advance path planning time of Mach3 specifies data size about motion path which the program needs to prepare beforehand The more the value the more stable the machine works e g when ToolPath picture rotates Mach stops calculating new trajectory data therefore the more of them were calculated beforehand there is the less possibility of failure in motion while rotating the picture or ...

Страница 6: ...r Servo motor Frequency converter CNC controller PC with installed CNC program MACH3 Power unit Limit sensor Up to 5 sensors connection 12V Ethernet USB LPT cable Connection via Relay up to 3 devices C o n t r o l LPT cable 220 Vacuum hold down Cleaner Cooling fan Spindle KRESS Coolant pump 220 220 Stepper servo motor driver Up to 4 drivers connection Switching regulator 48V 70V STEP DIR ENABLE ...

Страница 7: ... for what connection to change the settings FOR CORRECT WORK WITH PLCM CONTROLLER IT IS NOT RECOMMENDED TO PUT THE SWITCH IN AUTOMATIC POSITION You can assign your PC any address e g 192 168 10 XX 192 168 10 1 The last value can be different different from 10 11 and 12 192 168 10 10 and 192 168 10 12 addresses for PLCM devices established by the manufacturer Automatic address assignment installati...

Страница 8: ...in work mode as system loading of third party applies can cause delay of tasks execution in Mach3 which can lead to loosing connection with the controller You can use several network cards when testing and setting the system With help of Double click of left mouse button open network properties window Choose Internet protocols TCP IP and press Properties In the opened window displace the switch to...

Страница 9: ...ing with manufacturer s requirements 06 Terms of Warranty The warranty period is 12 months after purchasing and is valid only if all operational conditions and scheduled maintenance are strictly followed 1 General terms 1 1 In case of product acquisition as separate components Seller guarantees working ability of every component but does not assume responsibility for the quality of their joint wor...

Страница 10: ...consistent technical improvement You can always download our latest versions at www purelogic ru www purelogic ru Contacts Moscow 7 495 505 63 74 Voronezh 7 473 204 51 56 149 Office 160 Leninsky avenue Voronezh Russia 394033 Monday Thursday 8 00 17 00 Friday 8 00 16 00 Break 12 30 13 30 sales purelogic ru ...

Отзывы: