Purelogic PLCM-B1 Скачать руководство пользователя страница 2

3

PLCM-B1

 

Breakout board for PLCM-E3/E3p controller

2

19.04.13 revision

1. GENERAL INFORMATION

PLCM-B1 is a breakout board for CNC Ethernet/USB PLCM 

controller. It allows to involve optimal all inputs and outputs. 

Sockets are mounted on board for connection of 6 step/servo 

motor drivers, 15 optoisolated inputs, 16 optoisolated outputs, 6 

high-current relays and frequency converter for electric spindle 

control.

PLCM-B1 module allows to control up to 6 step/servo motor 

drivers (any with STEP/DIR/ENABLE interface). The module can 

be used for creation of such various X-Y-Z coordinate systems as 

the CNC machines, the label equipment, engraving, laser cutting, 

pick and place machines. 

The module supports operating with any step motor drivers 

and servo motor drivers of Purelogic R&D production, drivers of 

other manufactures.

2. DELIVERY SET

• PLCM-B1 breakout board – 1 pcs.

• PLCM-B1 User manual - 1 pcs.

3. TECHNICAL SPECIFICATIONS

TURN OFF POWER DEVICE BEFORE MAKING ANY CONNECTIONS
POWER SUPPLY NEGATIVE WIRE CONNECTION WITH GROUND 

(GND), HOUSING AND ETC. IS FORBIDDEN

!

Supply voltage

12V 

Maximum consumption current 

400 mA

Control interface

Ethernet/USB compatibility with CNC 

programs (for example MACH3)

Quantity of inputs

15, optoisolated inputs 

(optoсouple, 1 KOhm, 30V MAX ) 

Quantity of outputs

16, optoisolated outputs 

(optoсouple, 40 mA, 40V MAX ) 

Quantity of power outputs, relay

6, toggle, 6A/250V relay 

PWM → voltage converter

U output = 0...9,5 V (at on-off time 

ratio change Q=0...1), 10 V supply 

voltage by frequency converter

Isolation resistance

500 MOhm

Operating temperature

0 … 50 °С

Net weight

0,3 kg

Overall dimensions (Width x Height x Depth)

188 x 25 x 173 mm

Check wiki.purelogic.ru for more detailed information 

!

Содержание PLCM-B1

Страница 1: ... ru CONTENTS 1 General information 2 2 Delivery set 2 3 Technical specifications 3 4 Key features 4 5 Sockets purpose and indication 6 6 Connection 11 7 PWM voltage converter 13 PLCM B1 Breakout board for PLCM E3 E3p controller ...

Страница 2: ...vo motor drivers of Purelogic R D production drivers of other manufactures 2 DELIVERY SET PLCM B1 breakout board 1 pcs PLCM B1 User manual 1 pcs 3 TECHNICAL SPECIFICATIONS TURN OFF POWER DEVICE BEFORE MAKING ANY CONNECTIONS POWER SUPPLY NEGATIVE WIRE CONNECTION WITH GROUND GND HOUSING AND ETC IS FORBIDDEN Supply voltage 12V Maximum consumption current 400 mA Control interface Ethernet USB compatib...

Страница 3: ... by LEDs 15 optoisolated inputs for connection of limit switches and E STOP button Connection of optoisolated inputs operation external backup LEDs is provided 16 optoisolated outputs open collector States of outputs are indi cated by LEDs Frequency converter support adjustment of spindle rotations PWM voltage converter from control program MACH PWM signal Control of six high current relays 6A 220...

Страница 4: ...nnection and E STOP button connectors optoisolated inputs XP41 XP55 pin connector external LED of optoisolated input operation connection polarity is specified on the connection diagram anode cathode XP56 XP61 terminal socket K1 K6 relay load connectors XP62 XP77 terminal socket optoisolated outputs open collector XP78 terminal socket XP6 socket backup of PLCM E3 E3p module XP79 terminal socket fr...

Страница 5: ...9 PLCM B1 Breakout board for PLCM E3 E3p controller 8 19 04 13 revision Fig 2 General CNC control system diagram ...

Страница 6: ...tion spindles coolant pump or electric fan Relay states are indicated by LED29 LED34 according to fig 3 Relay loads are connected to XP56 XP61 pins Limit switches connection PLCM B1 has 15 inputs for XP 26 XP40 switches connection Physically each input is optocouple with built in transition resistor 1 KOhm depending on sensor type and sensor supply voltage the increase in resistance is probably re...

Страница 7: ... fig 2 Separate power supply unit with necessary voltage is strongly recommended to use for sensors supply 12V module supply can be used in an extreme case in this case optoisolation will not be Optoisolated outputs loads connection PLCM B1 has 16 optoisolated outputs in which loads are connected to XP62 XP77 Physically each output is an optocouple open collector type output This optoisolated outp...

Страница 8: ...spect Voronezh city 394033 Russia phone 7 495 505 63 74 7 473 204 51 56 e mail info purelogic ru Pay attention that documentation can be changed due to constant technical upgrading of production You can download last versions from www purelogic ru ...

Отзывы: