11
NOTICE:
For Canada, a 6 AWG or larger solid copper bonding conductor is required.
7. The pump should be permanently connected to either a circuit breaker, 2-pole timer or 2-pole relay. If AC
power is supplied by a GFCI circuit breaker, use a dedicated circuit breaker 3-that has no other electrical loads.
8. Connect the pump permanently to a circuit. Make sure no other lights or appliances are on the same
The field wiring compartment has a 1/2” NPT threaded
conduit port for the liquid tight fitting.
The bonding lug should be used to bond the motor
frame to the equipment pad.
OPERATING THE PUMP
Setting the Clock
When the pump is first installed, it is necessary to set the clock.
Any daily schedule set by the
user must be based on.
To Set the Clock:
1. When power is applied to the pump, the Time LED light will begin blinking and you must press the Display button
within 5 seconds to enter the clock setup mode.
(If Display button is not pressed within 5 seconds, you may
press "<" and ">" together for 3 seconds to begin again. The time LED light will begin blinking. Quickly press the
Display button within 5 seconds to enter the clock setup mode.)
2. Use the arrows to choose between a 12 or 24 hour time format.
3. Use the "+" and "-" buttons to change the displayed time to the correct time of day. In the 12 hour time format
AM/PM will display in the bottom left corner.
4.
To exit the clock setup mode, press and hold the Display button until the TIME light goes out. The clock is now set.
5.
In Schedule mode, Press START and allow pump to run on Default Schedule for at least one OFF-ON cycle. If
motor does not start, press any speed button.
ATTENTION:
Steps 1-4 are used for Schedule Mode and Manual Mode. Step 5 is only used for Schedule Mode.
During a power outage, the drive will retain the clock setting in memory for as long as 24 hours. If the power is out
longer than 24 hours the clock will have to be set again.
NOTICE
:
When power is returned to the pump after a prolonged outage (24+ hours) the clock will automatically
set itself to the Speed 1 start time, blink and advance. The pump will also run the associated schedule from that
start time.