Altec AIR
P8400W Air-dryer User’s Guide
Page 85 of 110
P017585 – Rev. A
10.3 8,000 & 16,000 Hour Maintenance
Under typical operating conditions:
8,000 hours of run time will occur between one (1) and two (2) years of use.
16,000 hours of run time will occur between two (2) and three (3) years of use.
This will be identified by a Compressor Total Hour Alarm on the display for either
System 1 or System 2
(section 8.5.9 )
.
MODEL:
P8400W
LOCATION NAME:
SERIAL NUMBER:
ADDRESS:
DATE INSTALLED:
Maintenance Interval (Hours)
Procedure
Section
8,000
16,000
24,000
32,000
40,000
Install 8,000 Hour Maintenance Kit
P011813
Install 16,000 Hour Maintenance Kit
P011814
Read & Record Flow Rate (
FLOW
)
Measure & Record
Compressor 1 Amp Draw
Measure & Record
Compressor 2 Amp Draw
Set System Pressure (50 PSI)
Set Static Pressure (17 PSI)
Set Outlet Pressure
Test Consistent Heatless Dryer Cycling
Test Compressor ON/OFF Cycling
Test Air Fittings for Leaks
Reset Total Hour Readings to Zero
System 1 & System 2
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
Maintenance Performed by:
Date of Maintenance:
NOTE:
COPY OR PRINT THIS PAGE AND KEEP IT WITH THE AIR-DRYER