9.6 Testing Consistent Heatless Dryer Cycling
With the System* Compressor running
(
System* = System 1 or System 2)
:
9.6.1
Remove Front Panel (see section 8.10.2 )
9.6.2
Disconnect the purge tubes
from the System* Heatless
Dryer.
9.6.3
Place your hand beneath the
purge fittings to feel for
purging air. Air should:
Purge from Tower 1 side
Purge from Tower 2 side
30 Seconds
later
Purge from Tower 1 side
30 Seconds
later
…and so on.
9.6.4
Re-connect the purge tubes
to the Heatless Dryer.
9.6.5
Reinstall Front Panel.
If the Heatless Dryer is not cycling consistently as described, see section 13.20
for troubleshooting information.