Pure Cold ICON6 Installation, Maintenance Manual 2022 | Issue Date: May 2022 REV 3

 

 

© Purecold Incorporated

 

Содержание 1OS7LA1

Страница 1: ...1 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 Purecold Incorporated...

Страница 2: ...2 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3...

Страница 3: ...nsibility for safe arrival If damaged claim must be made to the carrier Apparent Loss or Damage If there is an obvious loss or damage it must be noted on the freight bill or express receipt and signed...

Страница 4: ...vailable from Pure Cold Inc All information and diagrams contained within this manual are correct at the time of issue stated on the cover page Pure Cold Inc reserves the right to change case specific...

Страница 5: ...5 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3...

Страница 6: ...6 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 Case Lengths 123 3124mm 92 1 4 2344mm 61 5 8 1564mm Allow 2 50mm per endcap...

Страница 7: ...f evaporative tray may not manage the amount of water being produced and may overflow For California businesses This product may contain chemicals known to the State of California to cause cancer birt...

Страница 8: ...over the top of the cabinet into the store or if there it is large enough into the ceiling void The finished backs on these cases and oversized end caps ensure adequate air flow spac ing Icon fixture...

Страница 9: ...allation Maintenance Manual 2022 Issue Date May 2022 REV 3 TOOLS Forklift 10mm 13mm 16mm Sockets 10mm 16mm 24mm Wrench Impact Drill J Bar Construction Knife Phillips Bits Hacksaw Allen Wrench Set metr...

Страница 10: ...uld only be done by pre determined fork lift slots at rear of case Caution lifting from the underside of the cabinet may cause significant damage Extreme care should be taken to avoid damage to refrig...

Страница 11: ...2022 REV 3 Carefully remove clear wrapping and bubble panels from fixture exterior using knife Remove shipping brackets located on top of fixture with 7 16 socket Remove shipping vertical shipping br...

Страница 12: ...with 2 on left and 2 on right Correct position picture on bottom view 4 Air Guides help keep the drywall from being affected by cool stagnant air experienced in all Markets that can promote the growt...

Страница 13: ...with endcap Fixtures are fitted with permanent castors for pushing fixtures into final position Leveling Bolts should be wound down upon final positioning of fixture with 24mm open end wrench Icon Fi...

Страница 14: ...ium Low Temperature fixtures attach the foam rubber to the ends of the openings shown as red line on illustration on the left On Low Temperature Fixtures Only continue to apply an even amount of masti...

Страница 15: ...Insert case to case system divider Move the required case tightly against the line up case Insert all necessary joining 7 bolts as indicated in the illustration on the left and finger tighten Proceed...

Страница 16: ...HARDWARE KIT Locate bolts provided in Hardware Kit Insert all necessary joining 5 bolts nuts as indicated in the illustration below and finger tighten After adjustment and alignment have been achieved...

Страница 17: ...d ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 A Canopy to canopy cover strip and screws are supplied in the case to case fixing kit to ensure a flush and aligned finish to can...

Страница 18: ...Maintenance Manual 2022 Issue Date May 2022 REV 3 Fit Kickplate Fits magnetically to circular magnets located to front of wheel and feet assembly Plastic washer to metal kickplate to be at the bottom...

Страница 19: ...19 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 Front Panels Fitted Lift upwards onto slots...

Страница 20: ...er caps supplied for endcap line up Locate back mounting bracket and rounded cover plate Find slot on front lower panel to snap mounting bracket Secure mounting bracket with Phillips self tapping scre...

Страница 21: ...sh to floor Remove the red protective 3M tape Position infill on floor and slide on to end panel to underside of end walls as required Fixing infill wall endcap panels verti cally flush and tight fini...

Страница 22: ...22 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 16MM Wrench...

Страница 23: ...fog film be neath 3 To remove the outer protective film firmly grasp bent tab and carefully begin to slowly pull down toward the opposite lower corner of the door until outer film is re moved Cleaning...

Страница 24: ...ay 2022 REV 3 Five Shelf Tiered Profile Bay 1 Ticket Rail provided which slides onto shelf front molding before inserting into case Shelves to be 0 degree horizontally fitted The thermometer provided...

Страница 25: ...25 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 Locate Brackets on Gable Ends See Floor Bolt Diagram on Next Step...

Страница 26: ...26 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3...

Страница 27: ...27 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 Seismic Brackets Location...

Страница 28: ...ngle brace to each rectangle panel Re peat with other panel and triangle brace Place assemblies in dividually on top of seam where cases are joined together Attach each brace end panel with screws 3 R...

Страница 29: ...29 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3...

Страница 30: ...osition or an angle of 15 from vertical this period should be extended to 18 hours Untie electrical flex and place it in such a location so that it can be connected to the appropriately rated socket o...

Страница 31: ...ng this will eliminate any possible burning of these terminals after installation Plug and Chord connections should also be checked in case of any loosen ing from transport vibration The plug cord fit...

Страница 32: ...Issue Date May 2022 REV 3 Retaining Bolt for Slide Out Tray Isolater Switch Lift Off Front Panel Dust Debris Filter Slide Out Tray to Condensing Unit and Evaporative Tray Slide Out Tray For Electrical...

Страница 33: ...33 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 For Large Printable Media Click Here...

Страница 34: ...34 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 For Large Printable Media Click Here...

Страница 35: ...35 Pure Cold ICON6 Installation Maintenance Manual 2022 Issue Date May 2022 REV 3 For Large Printable Media Click Here...

Страница 36: ...Issue Date May 2022 REV 3 The standard refrigerant for the ICON6 case is R448a unless otherwise specified Check the serial plate located on case ceiling plate right hand side for information For addit...

Страница 37: ...Date May 2022 REV 3 Please refer to engineering cut sheet for energy data and total heat rejection values and refrigerant charge sizes Case controllers are pre programmed prior to dispatch Please fin...

Страница 38: ...ounting Do not load individual shelves with more than 200lbs Loading of Merchandise Where marked do not fill case beyond the load line label Always allow air space between the product and the shelf or...

Страница 39: ...ed personnel should carry out this process When cleaning cases only use non abrasive odorless detergent cleaner suitable for food hygiene envi ronments diluted to the manufacturers recommended concent...

Страница 40: ...and place flat on the ground 2 Remove mesh screen filter by lifting out of notched panel 3 Rinse filter with water from a medium pressure hose or sink 4 Gently dry filter with soft cloth DO NOT HIT OR...

Страница 41: ...re water hoses Do not use abrasive and or solvent cleaners that could scratch or irreversibly damage the surface finish Never use a cleaning or sanitizing solution that has an oil base these will diss...

Страница 42: ...orrect fuse rating and type is fitted for all circuits Ensure all fans valves lights blinds and controls are working correctly Check condenser for damage Check evaporator coil for damage Ensure that t...

Страница 43: ...ere may be a residual charge Unscrew 4 screws and slide out tray When working with the electric box ensure no strain is Refrigeration Tray Electrical Tray General Cautions The case contains some heavy...