MAINTENANCE

Electric Shock Is Life-threatening!

Before performing any operation on the device, please unplug the power plug from 
the socket. Do not bypass any electrical safety devices!

Inhalation Of Ozone Can Cause Injury!

Please perform regular maintenance and maintenance to ensure the normal 
operation and trouble-free operation of the equipment.

After the equipment stops running, please wait for a while to ensure that the ozone 
concentration is lower than the specified value, and then perform maintenance and 
cleaning.

The type and frequency of maintenance tasks basically depend on the operating 
environment and the time and type of use.
During use, dust and moisture will accumulate inside or inside the component, 
which may affect its function and efficiency.
In a dusty room or after repairing a fire (high humidity level), inspection and 
maintenance should be carried out immediately.

!

The basic principles for determining equipment operation and maintenance intervals:

often
Per hour
1-2 times a week
In an overly dirty environment
In a humid room

Regardless of the operating conditions described, you should perform maintenance if one or 
more of the following signs appear:

The noise level increases when the fan is running
Severely polluted soft magnetic stickers
Dirty electrodes (identifiable by hissing sound)
The substances produced during the ozone production process gradually disappear.

House Cleaning

Clean the case with a soft, damp, lint-free cloth. Make sure that no moisture enters the enclosure. 
Prevent electrical components from getting wet. Do not use any harsh cleaning agents, such as 
cleaning sprays, solvents, alcohol-based cleaning agents, or abrasives to soak the cloth.

Cleaning

Within the framework of regular maintenance work, it is not only necessary to check the normal 
condition of the equipment and its accessories, but also to thoroughly clean the equipment and its 
components.

Proceed As Follows:

Disassemble and clean the fan. Always check whether the fan is working properly. If it is only 
slightly contaminated, you can use a vacuum cleaner or a tap to clean it. If the contamination is 
serious, clean the reaction generator with a soap solution. After cleaning, insert the fan only 
after it is completely dry!

Remove the screws on the dust cover.
Remove the shell.

Clean the fan

1

2

3

Clean Electrode

Do not use the device before the electrodes are completely dry.

Make sure that there are no obstructions at the air inlet and outlet.

Do not install this machine near flammable substances or gases.

Make sure to place the device on a dry and vibration-free surface.

The electrode can be cleaned in the built-in state. Before cleaning the electrode, check for cracks. 
Do not use damaged parts!

Use a dry (lint-free) or damp cloth to clean the components. After cleaning, make sure that no fibers 
(fluff) remain on the electrode.

The following requirements must be met when installing the PureAiro Guardian 300:

Only use the PureAiro Guardian 300 according to the parameters provided in the "Technical Data" 
chapter.

If possible, place the device in the center of the room to ensure optimal air circulation.

Ensure that the equipment is protected from splash water.

TRANSPORTATION AND STORAGE

Pay attention to information about transportation and storage.

If you store or transport the device incorrectly, the device may be damaged.

Transportation
Before

 transporting the equipment, please observe the following regulations:

Turn off the device

If the device was in use before, please wait until the timing period is over before transferring the 
device.
Do not drag the device with the power cord during transportation to prevent the device from 
moving and vibrating to avoid damage to the electrode.

Hold the power plug while unplugging the power cord from the power outlet.

After 

transporting the equipment, please observe the following regulations:

Install the equipment in an upright position after transportation.

Storage

When the device is not in use, please observe the following storage conditions:

Store the PureAiro Guardian 300 in a dry place to avoid the influence of bad weather, and cover 
it to protect it from invasive dust. 
When the equipment is not in use, always disconnect the power supply.

Содержание GUARDIAN 30

Страница 1: ...Installation Operations Manual GUARDIAN 300 PureAiro solutions inc Add Berlin Germany Tel 44 20 81247965 E mail sales PureAiro com...

Страница 2: ...NTENTS 01 00 PureAiroGuardian300 Device Description Operation Mistakes and shortcomings Maintenance Transportation And Storage Technical Annex Electrical wiring diagram Limited Warranty 01 02 05 06 07...

Страница 3: ...ely 30 to 60 minutes This means that the ozone concentration in indoor air is naturally reduced by at least half every hour After the reactant oxidizes the oxygen atoms the ozone molecules will be con...

Страница 4: ...ase unplug the power plug from the socket Do not bypass any electrical safety devices Problem Cause Device does not work The fuse is blown The power plug is damaged Solution Replace the damaged fuse a...

Страница 5: ...king properly If it is only slightly contaminated you can use a vacuum cleaner or a tap to clean it If the contamination is serious clean the reaction generator with a soap solution After cleaning ins...

Страница 6: ...tput Operating Temperature Sound Pressure Level Service Life Size For Dimensions l w h Minimum Distance From Walls And Other Objects Top a Rear b Sides c Front d Value 220V 50HZ 55 130CFM 220CMH 5 000...

Страница 7: ...aused by misuse abuse neglect alterations or unauthorized repair 1 Damage caused by the owner when attempting to fix or alter the product by himself or herself How to request warranty services To obta...

Страница 8: ......

Отзывы: