OPERATING INSTRUCTIONS

Press this button to switch the unit into continuous mode.

Use this button if the unit will not be in use for an extended period of time. Pressing the drain 
pump button will remove
water from the pump reservoir, so the unit can be safely moved or stored. 
THIS FUNCTION IS ONLY AVAIL .ABLE ON THE Sentinel HDi90 model.

CONTINUOUS

DRAIN PUMP

c

P

Cont.

will appear on the display to indicate continuous mode.

Press the power key to turn the machine on.

START THE MACHINE

Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).

ADJUST THE SETTINGS

Press the power key again and the machine will stop. Note the fan will continue to operate
for 1 minute after the unit has turned off. NOTE: Do not disconnect the power cord to force
unit to stop. Always use the power button.

STOP THE MACHINE

During normal operation, the PureAiro DSC 55S will automatically drain by the force of 
gravity.If you want to move or store your machine, wait at least 10 minutes to allow the 
machine to completely defrost, then lean unit gently towards drain to ensure that it is 
completely drained.

WATER DRAINAGE

PUREAIRO  DSC  55S  DIAGRAM

REMOTE CONTROL INSTRUCTIONS

When the compressor light glows red, it indicates the compressor has been initiated but is 
currenty warming up.
Once the compressor light switches to green, it indicates the compressor is in working 
status.

Sentinel Dehumidifiers can be controlled using an optional remote accessory.The Sentinel 
Remote Control connects to your Sentinel Series Dehumidifier via a 25' CAT 5 cable. The 
remote control contains an integrated sensor which gives you multiple options for remotely 
controlling your unit, in addition to monitoring the conditions surrounding the dehumidifer.

One application for the remote control is to install the dehumidifier in one room with the 
conditioned air ducted into a second room that contains the remote. For example, the 
dehumidifier could be installed in a laundry room and ducted into a living room. The remote 
would then be mounted in the living room so the remote sensor can control the humidity and 
provide easy controls for the user.

COMPRESSOR LIGHT

Another useful application for the remote control is if the dehumidifier is in area that's 
difficult to access on a regular basis. For instance, if your dehumidifier is installed in your 
crawl space, the remote could be mounted in your living space or garage. This provides you 
with an easy way to monitor the dehumidifier.

Press the on/off button and the machine will 
start running (one beep). Press the button 
again to the turn the machine off.

Use the Up and Down arrow buttons to adjust 
the humidity level.

ON/OFF (POWER)BUTTON

UP BUTTON▲ / DOWN BUTTON

Use the Mode button to switch between 
dehumidification and a ducted application.

MODE

The

   

symbol on the display board indicates 

the sensor on the remote control is being 
utilized.
The

  

symbol on the display board indicates the sensor on the dehumidifier is being utilized.

TEMPERATURE

Press the temperature button to display the current temperature on the screen. Press the 
button again to turn off the display.

PureAiro 

DSC 55S

4

1

2

3

M

4

T

5

6

NOTE: Symbols indicated above will only appear when the dehumidifier is powered on.

1

2

3

4

DRAIN PUMP

MODE

LCD MONITOR

CONTINUOUS

TEMPERATURE

DOWN BUTTON

UP BUTTON

ON/OFF

06

07

Front View

POWER CORD

CONTROL PANEL

REMOTE CONTROL

A5/A6 AUX.TERMINAL

FOR OPTIONAL COND.PUMP

DRAIN CONNECT

UNIT COVER

HABDLE

Содержание DSC 55S

Страница 1: ...ion Compatible with Remote Control Notice sold separately Coated coils with the stainless side plate Engineered for low temperature operation and the air ow issues like the crawl space or attic Multip...

Страница 2: ...uctural integrity Increased humidity levels indoors can cause the growth of mold and mildew and an increase in dust mites These are known allergens that cause respiratory problems and asthma This is w...

Страница 3: ...Dehumidi ers should only be maintained and repaired by a quali ed technician Sentinel Dehumidi ers are only intended for operation when oriented with the unit stting on its feet and level Operating t...

Страница 4: ...is powered on it shows the humidity of the space 2 While setting the desired humidity level the screen wil show the set humidity After a brief delay the display will revert to current humidity level W...

Страница 5: ...ves you multiple options for remotely controlling your unit in addition to monitoring the conditions surrounding the dehumidifer One application for the remote control is to install the dehumidi er in...

Страница 6: ...to pull out and down on base of adapter This will lift hooks out of cover holes INSTALLING SUPPLY DUCT ADAPTER To install adapter line up with holes on the side of unit and push up from base of adapte...

Страница 7: ...according to instructions listed in manual Air Filter is Clogged Low Air Flow Clear the blockage from inlet or outlet Machine is Not Level Loud Noise Check to ensure that wire is connected at both en...

Страница 8: ...refrigerant CUSTOMER RESPONSIBILITIES In order to take advantage of the warranty service the customer must do the following Customer must provide normal care and maintenance including but not limited...

Отзывы: