![Pure Water 21598 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/pure-water/21598/21598_operators-manual_1627144009.webp)
Important Note:
If the unit is hot, turn the power OFF and allow it to cool before
draining the boiling tank.
1. Turn the Power Switch to OFF.
2. Turn the valve on the back of the AquaNui and allow the residue to drain into a
sink, drain or bucket.
3. Close the valve.
4. Turn the Power Switch to ON.
Changing the VOC Filter
1. Turn the Power Switch to OFF.
2. Turn the water o
ff
at the wall valve.
3. Disconnect the
lter from the tubing.
4. Connect the inlet tube to the inlet side of the new
lter.
5. Hold
lter over a bucket or drain.
6. Cycle water on and o
ff
several times until water fromt he outlet of the
lter is clear.
7. Connect outlet of
lter to tubing.
8. Turn water and power ON.
Cleaning the Boiling Tank
Notes and Cautions:
Caution: Under no circumstances should the cleaning solution be heated and
run through a steam sterilization or distillation cycle.
Note:
Failure to clean the boiling tank can result in scale build-up causing prema-
ture heating element failure, as well as reduced purity of the distilled water due to
the possibilities of splash over of contaminants from the boiling tank.
To clean the boiling tank:
1. Turn the Power Switch to OFF. If needed, allow the unit to cool.
2. Drain the boiling tank (see instructions above).
3. Remove the back panel of the distillation unit.
4. Disconnect the boiling tank wire harness, inlet tube, and steam tube. Remove the
boiling tank.
5. Manually
ll the boiling tank until the scale is covered by water.
6. Add 2 Tablespoons of Lumen® descaler to the boiling tank. Allow to sit overnight.
7. Drain all of the water from the boiling tank.
6. Install the nuts onto the 4 positioning studs on the storage tank. Tighten to con-
nect the storage tank and distiller together.
7. Remove the boiling tank lid. Remove
the wire tie that is holds the
oat dur-
ing shipping. Replace the boiling tank
lid.
8. Connect the Distillate Tube (silicone
tubing from the condensing coil outlet)
to the storage tank inlet tube. Use the
metal clamp to secure the connection.
9.
Connect the 3 pin connectors together. This will allow the distiller to read the
probes in the storage tank.
10.
Install the boiling tank into the distiller.
11.
Connect the Steam Tube.
12.
Connect the Water Inlet tubing and
tting.
13.
Connect the Boiling Tank 5 Pin Harness.
14.
Place the back panel onto the distiller and secure with the 4 screws.
Connecting the Raw Waterline:
CAUTION: DO NOT use a hot water line
for your supply line.
CAUTION: DO NOT turn the saddle
tapping valve handle before or during
installation. Be sure the piercing lance
does not protrude beyond the rubber
gasket. Failure to do this may result in
damage to the piercing needle.
Note:
The use of so
ft
ened water for the raw water supply is recommended to
minimize scale build-up in the boiling tank and drain valve.
Note:
The Pure Water AquaNui comes standard with a saddle tapping valve.
In some areas a saddle tapping valve may not be permitted. In such instances,
contact your authorized AquaNui Sales Associate, Pure & Secure, or go to www.
myaquanui.com for other water line connection options.
Note:
Do not plug the unit into the power source until instructed to do so.
1. Install the saddle-tapping valve per the instructions on the bag.
2. Cut a 5” piece of the 1/4” tubing.
Note: The use of so
ft
ened
water is recommended to
minimize scale
build-up in the boiling
tank and drain valve.
Every 3 Months:
Clean the boiling tank.
12
9
Every 3-6 Months:
Change the VOC Filter.
Note: The
oat ball in the
boiling tank is tied down
for shipping. The tie must
be removed before the
distiller is used.
Storage Tank
Red-High (OFF)
Yellow-Low (ON)
Green-Common
Distillate Tube
Air Filter
metal clamp