3
© Pure Water Systems Australia. V1 - PWS00031
Flathead
screwdriver
Different
sized rubber
fittings
C. No Thread - Small Tap Diameter (TA2 Adaptor)
1. Select the correct sized black grommet to fit on the TA2 internal tap
adaptor which will then go up into the inside of the tap (there are 3
different sized black grommets that can be used for different sized taps).
2. Push the black end of the adaptor up inside of the tap.
3. Using a flathead screwdriver on the silver plate, tighten clockwise (this is
a reverse thread) until the black grommet widens and holds firmly to the
inside of the tap.
4. Attach the diverter to the bottom of the tap adaptor.
5. Complete the installation process
(Refer Step 3)
.
B. Internal Threaded Tap (TA1 Adaptor)
1. Place the rubber washers into the TA1 tap adaptor (thin first, then the
thicker washer).
2. Screw the tap adaptor up into the inside of the tap and tighten.
3. Attach the diverter to the bottom of the tap adaptor.
4. Complete the installation process
(Refer Step 3)
.
A. External Threaded Tap
1. The clear washer comes pre-installed into the top of the diverter valve.
Ensure that it is seated correctly.
2. Screw the diverter straight up onto the end of the tap.
3. Complete the installation process
(Refer Step 3)
.
If the diameter of the tap is too big to fit the diverter, please go to installation
D.
STEP 2. Continued
Extra
internal
sleeve
D. No Thread - Large Tap Diameter (TA3 Adaptor)
1. The TA3 tap adaptor comes with a small internal sleeve which can be
removed for larger taps.
2. Push the black washer into the inside of the TA3 tap adaptor.
3. Push the tap adaptor up and over the outside of your tap as far as
possible.
4. Slip the steel clamp over the white rubber adaptor as high as possible on
the adaptor to avoid splitting.
5. Using a screwdriver, tighten the clamp firmly.
6. Attach the diverter to the bottom of the tap adaptor.
7. Complete the installation process
(Refer Step 3)
.