1. UV Intensity (%) - UVSS-M Models Only:

The UVSS-M models incorporate a UV sensor which detects the discrete 254 nm wavelengths of the UV lamp. This
information is relayed to the controller and is the default display shown in “% UV output”. The system will display the UV
output between 50 to 99 percent. When the system drops below 50%, a low UV warning is displayed as [  

A2

] and alter-

nately flashes (at 2 second intervals) back to the actual UV level. 

Example:

49

] Additionally, the system will supply an intermittent audible tone (2 seconds on, 2 seconds off), during low

UV conditions.

NOTE:

UV levels of:

[  

65 

] to [  

99

] Indicates the system is functioning within a normal operating range.

[  

56

] to [  

64

] Indicates the UV level is still within a safe level, however cleaning or lamp replacement may soon

be required.

[  

50

] to [  

55

] Indicated the UV level is nearing the point of unsafe UV intensity, UV system should be immediate-

ly serviced.

< [  

49

] Indicates the UV level has now reached a level that is unsafe. At this level the water should not be

consumed. The system/water supply should be examined to determine the reason for the low UV
level of the UV intensity. At this level, the solenoid output has been activated and if a solenoid is
installed, water will cease to flow.

DEFERRAL

- To temporarily defer the audible alarm during a low UV alarm, press the push-button “RESET” switch and

hold for five seconds. This will mute the audible alarm condition for 12 hours.

CAUTION:

This advanced warning system has been installed to provide you with the optimum protection against microbiological
contamination of you water.

DO NOT DISREGARD THE WARNING SIGNALS.

The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing
agency on a regular basis.

Possible causes for low UV alarm conditions:

a) The UV lamp has perhaps reached a level whereby it can no longer adequately provide a sufficient level of disinfec-

tion due to age (> 9000 hours). The lamp should be replaced with a new lamp from the manufacturer of the same size
and type.

b) The quartz sleeve and/or the sensor window have become stained or dirty. Mineral deposits or sediment in the water

that was not detected during the original water analysis may be the cause for this (refer to page 5-6 for cleaning
instructions).

c) Intermittent voltage drop in the household power supply reducing the lamp output. The lamp will return to normal when

the power is restored to full voltage. 

Note: the monitoring system will not operate during power failures.

d) The quality of the influent water has changed and is no longer within the acceptable operational range of the UV sys-

tem. Perform a water analysis to determine the exact constituents and concentration levels.

e) The UV sensor is not installed correctly (see page 6).

99

Electronic Control Box Operation – UVSS-M Models

Содержание UVSS-10

Страница 1: ...INSTALLATION MANUAL OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System UVSS 6 UVSS 10 UVSS 15 UVSS 6M UVSS 10M UVSS 15M 51975 Rev 10 08 ...

Страница 2: ...ywhere in the world It has been designed with you the consumer in mind PURA products are lightweight easy to use and simple to maintain PURA products will pro vide you with healthy clean drinking water for years to come What is Ultraviolet Ultraviolet UV light from the sun has long been known for its ability to destroy microorganisms However it has only been in recent years that equipment producin...

Страница 3: ...ded see Figure 1D The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination see page 4 For safety purposes the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor use only do not install disinfection sys...

Страница 4: ... water matches the flow direction as indicated on the flow restrictor Figure 1C DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE SYSTEM AS THIS COULD DAMAGE THE O RING SEALS 4 Mount the controller horizontally on the wall near the reactor chamber Ideally place the controller above the reactor and away from any water connection point to prevent any water from potentially leaking onto the controller ...

Страница 5: ...of this water is not advised due to the extremely high concentration of chlo rine It is important to remember that in the event that a UV is briefly shut down for routine cleaning or during power interruptions where water could have passed through the system the aforementioned procedure must also be fol lowed Note A The addition of chlorine bleach to a hot water tank that has in the past been fed ...

Страница 6: ...the inside of the quartz sleeve causing the sleeve to fracture 3 To install a new lamp first remove the lamp from its protective pack aging again being careful not to touch the lamp glass itself Carefully insert the lamp into the reactor vessel actually inside the quartz sleeve Figure 2C Insert the lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber Next at...

Страница 7: ...ning UVSS M Models Only CAUTION The UV sensor is a very delicate instrument Extreme care is required when handling and cleaning The sensor window itself is constructed from quartz which is extremely fragile be careful you do not chip or break this quartz window Manufacturer s warranty does not cover damage due to neglect or misuse Mineral deposits and sediment may accumulate on the sensor window d...

Страница 8: ... lamprecycle org for lamp disposal c Install new UV lamp and connect it to lamp connector refer to page 5 d Replace lamp connector e Hold down the RESET switch while reapplying power to the controller until you see rSEt then release f 5 second delay will occur until you hear an audible tone LED display will read 365 once again Once you hear the tone let go of the switch and the counter will be res...

Страница 9: ...s the push button RESET switch and hold for five seconds This will mute the audible alarm condition for 12 hours CAUTION This advanced warning system has been installed to provide you with the optimum protection against microbiological contamination of you water DO NOT DISREGARD THE WARNING SIGNALS The best way to ensure optimum UV performance is to have the water microbiologically tested by a rec...

Страница 10: ...g AC power flowing to the normally closed solenoid valve The valve will remain closed no power until the UV level rises above 49 at which time the solenoid will open allowing for water to pass through To temporarily defer the operation of this solenoid output for up to 12 hours please refer to the instructions outlined on page 8 of this manual NOTE DURING BYPASS the water should NOT be consumed un...

Страница 11: ...3 Heated Product Water A Common problem caused by infre quent use of water A Run water until it returns to ambient temper ature 4 Water Appears Milky A Caused by air in the water lines A Run water until air is purged 5 Unit Leaking Water A Problem with o ring seal on gland nut and or UV sensor B Condensation on reactor chamber caused by excessive humidity and cold water C Inadequate inlet outlet p...

Страница 12: ... 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 11 Connector 4 pin 89072 Solenoid Valve optional 3 4 120V Solenoid Valve optional 1 120V Solenoid Valve optional 3 4 230V Solenoid Valve optional 1 230V 89528 89529 ...

Страница 13: ...Models Alternate Powercords Available 3 4 NPT Outlet 1 NPT on UVSS 15 Ground Wire Length 32 19 2 UVSS 6 32 9 UVSS 10 35 0 UVSS 15 3 4 NPT Inlet 1 NPT on UVSS 15 Ø2 50 Ø3 50 on UVSS 15 1 7 6 3 4 10 9 2 5 8 Connector 4 pin 89072 ...

Страница 14: ...dealer the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PRODUCT AND COMPONENTS DESCRIBED IN THIS LIMITED WARRANTY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a...

Отзывы: