Inlet Water Supply

CAUTION:

  ONLY USE COLD WATER LINE. IF YOU CANNOT TELL WHICH LINE IS 

THE COLD, TURN ON WARM WATER AND FEEL FOR WARMTH.

1 - Locate the cold water line and shut-off valve for faucet. 
Shut off water supply. Turn cold water on at sink to release 
pressure.
2 - From parts bag, locate: 

” x 

¼

” x 

”  ANGLE SUPPLY VALVE.

3 - Disconnect 

” tubing from existing cold water shut-off.  Insert ANGLE VALVE 

on the male thread of the existing cold water supple valve. Now, fasten the loose  

” tubing to the TOP of the ANGLE VALVE.

4 - Connect 

¼

” tubing to the port in the ANGLE VALVE. 

5 - Turn OFF BLUE VALVE.
6 - TURN ON cold water supply. making sure there are no leaks.

NOTE:

  THE ABOVE INSTALLATION STEPS ARE FOR COPPER AND PLASTIC 

PLUMBING INSTALLATION ONLY. TO INSTALL IN IRON PIPE, YOU WILL NEED TO 
DRILL A HOLE FOR THE PIERCING POINT.

System Start-Up

1 - Turn on cold water supply.
2 - Make sure the tank ball valve is in the 

OFF

 position.

3 - Turn ON dedicated faucet, wait until the water flows to a steady trickle. 
4 - Turn off the faucet - this will allow the system to PRESSURIZE. At this time, 
 

check the system for leaks. 

5 - Turn the tank ball valve to the 

ON

 position.

6 - It will now take several hours (2-3) for the storage tank to completely fill, 
 

depending on the local water pressure.

7 - After the tank is filled, turn on the dedicated faucet and

 allow the pressure 

tank to completely drain

. This will take about 5 minutes.

CAUTION:

 DO NOT DRINK THE WATER FROM THE FIRST TANK PRODUCED BY 

YOUR NEWLY PURCHASED SYSTEM.

 

 

 

 

 

 

8 - Turn OFF the dedicated faucet.
9 - REPEAT Steps 7 & 8.
10 - Wait for the pressure tank to fill again.  
 

You are now ready to enjoy the water.

7 - Check for leaks for the first several days and periodically thereafter.
8 - You may notice that the water may be milky colored during the first week. 
This results from air bubble in the water. It is normal and safe.

-8-

Содержание Alkaline Plus

Страница 1: ...for the reverse osmosis membrane Stage 2 Pre Carbon filter contains granular activated carbon to remove chlorine and other chemical contaminants protecting the Reverse Osmosis Membrane Stage 3 The Rev...

Страница 2: ...e osmosis Membrane is changed every 3 years Quick Connect Secure Fittings 1 Confirm the tubing ends are cut squarely NOT at an angle and without burrs 2 Firmly insert the end of the tubing into the Qu...

Страница 3: ...unit to the DRAIN SADDLE VALVE 2 From the T connection coming from the OUT port connect tubing to either WHITE PORT on the T connection to the shut off valve fitting on the Pressure TANK 3 From the T...

Страница 4: ...nects the system to your cold water line under your sink This device will self pierce copper and plastic plumbing Drain Saddle Valve This connects to your drain plumbing and allows reject water flow t...

Страница 5: ...ILL OR CORDLESS DRILL TO MAKE THE HOLE IF YOU USE AN ELECTRIC DRILL OUTLET MUST BE GROUNDED ALWAYS USE SAFETY GLASSES OR OTHER EYE PROTECTION WHEN DRILLING TO PREVENT POSSIBLE EYE INJURY FROM FLYING P...

Страница 6: ...PEN END HARD PLASTIC WASHER LOCK NUT WAHER and HEX NUT onto the stem of the faucet Tighten securing the faucet to the sink counter top 3 In the PARTS bag take GRAY plastic Faucet Connector and screw i...

Страница 7: ...horizontal tail piece 3 The position of the hole on the pipe should be marked and drilled with a bit through only one side of the pipe 4 Align the drain saddle valve over drilled hole and attach it t...

Страница 8: ...tart Up 1 Turn on cold water supply 2 Make sure the tank ball valve is in the OFF position 3 Turn ON dedicated faucet wait until the water flows to a steady trickle 4 Turn off the faucet this will all...

Страница 9: ...or temperatures can reduce production rate Add pressure to storage tank The pressure should be 5 7 psi when the tank is empty Slow production Low water pressure Crimps in tubing Clogged pre filters F...

Отзывы: