BENEFITS 

 

Helps provide relief from allergy, asthma and respiratory 

illness. 

 

Helps clear a smokey environment quickly, so everyone 

can work and relax together. 

 

Helps  reduce  the  time  and  money  spent  cleaning  and 

redecorating.    Prevents  damaging  black  dust  from 

staining walls, upholstery and window coverings. 

 

Helps reduce tobacco, cooking and pet odors. 

 

Revitalizes the air with healthy negative ions. 

 

Improves  indoor  air  quality  for  a  fresher,  more 

comfortable environment, year-round. 

HOW IT WORKS

 

Dirty air is drawn in through the front grill and passes through 

a 4-stage filtering system. 

The  Prefilter  consists  of  aluminum  mesh  and  a  close  knit 

polymesh.    It  prevents  larger  particles,  lint  and  hair  from 

entering the collecting cell. 

The next step is a 2-Stage Electrostatic Collecting Cell.  Dirt 

particles are charged with a high positive voltage by a series 

of  fine  ionizing  wires.  The  charged  particles  are  drawn 

through to the collecting plates where the dirt adheres to the 

grounded plates, and remains until the cell is taken out and 

washed.  Removes  particles  down  to  0.01  micron 

(1/2,540,000 of an inch). 

The  air  is  then  drawn  through  an  Activated  Carbon  Odor  & 

Gas  VOC  (Volatile  Organic  Compound)  Removal  Filter  to 

help  remove  offensive  odors  and  gases.    Clean  air  is  then 

discharged out the top of the Air Cleaner. 

Dual  Negative  Ionizer  is  located  in  the  clean  air  stream.  

Adding  healthy  negative  ions  to  the  air  revitalizes  the  air 

similar  to  that  near  a  waterfall,  spring,  the  ocean,  or  after  a 

rainfall.    Studies  have  shown  that  negative  ions  have  a 

beneficial effect on human biochemistry, both physically and 

mentally. 

OPERATING INSTRUCTIONS 

1.  Remove  the  Air  Cleaner  from  the  box  and  check  for 

apparent damage.  If your unit has any signs of damage, 

immediately contact the store where the Air Cleaner was 

purchased. 

2.  Keep  the  shipping  carton  in  case  the  need  arises  to 

store or transport the unit. 

3.  Remove all packaging from the unit.  Choose a suitable 

table or stand to allow unobstructed circulation from front 

and top of unit.  The unit performs best when the back is 

against a wall.  This enhances air circulation.  To mount 

unit on wall, refer to the Wall Mount Instructions. 

4.  Operate Air Cleaner at voltage shown on back of unit. 
5.  The  System  Switch  controls  the  power  to  the  Fan 

Control Switch and the power board.  When the System 

Switch is 

ON,

 the green light behind the front grill will be 

illuminated. 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - Lid which activates Safety Interlock 

 

2 - Negative Ion Emitter 

 

3 - Negative Ion Control Switch 

 

4 - 3-Speed Fan Control Switch 

 

5 - System Switch 

 

6 - Operation Lights 

6.  The  Fan  Control  Switch  in  the  front  position  is  low 

speed,  the  center  position  is  medium,  and  the  rear 

position is high speed. 

7.  The  negative  ions  are  controlled  by  a  separate  switch 

located behind the fan control switch.  When the switch 

is 

ON

,  the  red  light  will  be  illuminated.   

Note:    The 

Negative  Ion  Emitter  will  not  work  without  the 

System Switch being ON.

 

8.  To access the prefilter, collecting cell or activated carbon 

filter, press firmly on the right front dimple on the lid and 

release.  Lift the lid releasing it from the magnet. 

WALL MOUNT INSTRUCTIONS 

1.  To  mount  Air  Cleaner  on  wall,  remove  the  rear  feet  (2) 

from  the  bottom  of  the  Air  Cleaner,  to  expose  the 

keyhole slots. 

2.  To remove the feet from the Air Cleaner, you will need a 

small, flat screwdriver.  Pry up the center pin of the rear 

foot  until  the  head  protrudes  above  the  foot.    Place  the 

flat portion of the screwdriver under the foot and pry up.  

This will release the foot from the cabinet.  Keep the feet 

in case you wish to table mount the unit in future. 

3.  Find the location on the wall where you wish to place the 

Air  Cleaner.    The  unit  should  be  placed  3  feet  (1  m) 

below the ceiling.  Use appropriate fasteners for the type 

of  wall  the  unit  will  be  mounted  and  insure  the  head  of 

the  screw  will  fit  into  the  larger  opening  of  the  keyhole 

slot.  The screw head should be larger than the smaller 

opening  of  the  keyhole.    The  Air  Cleaner  weighs 

approximately 20 lbs (9 kg).  The distance between the 

holes in the cabinet bottom is 16 3/4 in (42.5 cm). 

4.  After placing the screws in the wall, adjust the amount of 

the  screw  sticking  out  to  approximately  1/8  in  (.32  cm).  

Place the Air Cleaner over the screw head and allow the 

head  to  slip  into  the  keyhole  slot.    Pull  the  unit  down 

slightly to allow the screw head to slide into the smaller 

portion of the slot.  

Use  the  low  or  medium  speed  for  quiet,  continuous  or 

nighttime use. Use the high speed for initial cleaning of heavy 

concentrations  of  dirty  air  (i.e.  smoke)  or  after  leaving  the 

room. 

1 Dirty Air 

 

 

 

2 Prefilter 

 

 
3 Ionizing 

   Section 

4 Collecting Cell 

   Plates 

 

5 Odor & Gas 

   Removal Filter 

 

7 Negative Ions 

   and Clean Air 
6 Ionizing Needle 

You may notice arcing or snapping from the cell.  It is normal 

to  hear  some  arcing  when  the  unit  is  new  or  first  turned  on.  

Arcing in the cell may  also  be caused by high humidity (over 

80%), after washing, or when a large particle of dirt or hair is 

caught  in  the  cell.    If  the  arcing  is  continuous  and  constant, 

then refer to the Troubleshooting Chart. 

Содержание PD-590AIV

Страница 1: ...more down to 0 01 micron Activated Carbon Odor Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative Ionizer restores the air s...

Страница 2: ...ch activates Safety Interlock 2 Negative Ion Emitter 3 Negative Ion Control Switch 4 3 Speed Fan Control Switch 5 System Switch 6 Operation Lights 6 The Fan Control Switch in the front position is low...

Страница 3: ...handle with care TROUBLESHOOTING CHART The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating but the lights do not come on...

Страница 4: ...Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operatio...

Страница 5: ...de tabac de fum e et de graisse de cuisson et plus aussi infimes que de 0 01 microns Le filtre pour odeurs et gaz charbon actif COV permet d liminer les compos s organiques volatiles provenant de sou...

Страница 6: ...gatifs 3 Interrupteur de commande pour ions n gatifs 4 Interrupteur de commande du ventilateur 3 vitesses 5 Interrupteur du syst me 6 T moins lumineux de fonctionnement 5 est la position ON marche le...

Страница 7: ...nement situ derri re la plaque signal tique l avant servent aussi indiquer un d faut de haute tension Si le ventilateur fonctionne mais les voyants ne s allument pas ceci signifie qu il y a un probl m...

Страница 8: ...molles comme lits canap s 12 N utilisez pas le purificateur d air lorsque de l oxyg ne est utilis ou lorsque des gaz combustibles sont pr sents 13 Le bo tier du purificateur d air est muni de fentes o...

Отзывы: